CDM-840 Remote Router Revision 2
Serial-based Remote Product Management MN-CDM840
7–27
7.3.10 Bulk Configuration String Commands
Parameter
Type
(Instruction
Code
Arguments for
Command or
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Command
(Target to
(Instruction
Code &
Response to Query
(Target to Controller)
Load
Retrieves a previously stored modem configuration from Configuration Memory
location defined by the one-byte argument (0 to 9).
Example: <1/CLD=4’cr’
CLD?
CLD*
CLD#
Save
Stores the current modem configuration in Configuration Memory location
defined by the one-byte argument (0 to 9).
CST?
CST*
CST#
7.3.11 Redundancy Commands and Queries
Parameter
Type
(Instruction
Code
Arguments for
Command or
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Command
(Target to
(Instruction
Code &
Response to Query
(Target to Controller)
State
Returns the redundancy state of the unit in the form x, where:
0=Offline
1=Online
(see description
of Arguments)
Switch
Forces the unit to toggle the Unit Fail relay to the “fail” state for approximately
500ms.
If the unit is a 1:1 pair and it is currently the ‘Online’ unit, this forces a
switchover so the unit will then be in ‘Standby’ mode.
The command is always executed by the unit regardless of whether it is stand-
alone, in a 1:1 pair, or part of a 1:N system.
Note: This command takes no arguments.
FSW*