CDM-840 Remote Router Revision 2
Serial-based Remote Product Management MN-CDM840
7–26
Parameter
Type
(Instruction
Code
Arguments for
Command or
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Command
(Target to
(Instruction
Code &
Response to Query
(Target to Controller)
Es/No
Returns current Es/No of demodulator where:
s = ‘0’ or ‘-‘ (negative sign, if needed, zero otherwise)
xx.x = value from 00.0 to 35.0 dB.
Resolution = 0.1 dB.
Returns 999 if demod is unlocked.
Returns 35.0 for values greater than 35.0dB.
Note: This query provides a fast Es/No reading that is updated in the background
10 times per second, and is also averaged in the background over the previous 16
returned values.
(see Description of
Arguments)
Community
no spaces
SNMP read community string.
Example: <1/SRC=public
Note: Empty string is not allowed.
SRC!
(see Description of
Arguments)
Write
Community
characters, no
spaces
SNMP write community string.
Example: <1/SWC =public
Note: Empty string is not allowed.
SWC!
(see Description of
Arguments)