Comtech EF Data CDM-700 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Sítě Comtech EF Data CDM-700. Comtech EF Data CDM-700 Product specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 266
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - CRS-300

IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifica

Strany 2

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM viii 7.3 SELECT (Top-Level) Menu ...

Strany 3

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–40 4.6 CDM-Qx/QxL Modem Connections If adding a modem to an ope

Strany 4

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–41 Figure 4-16. EIA-485 Multi-drop Cabling Example – CRS-

Strany 5 - Table of Contents

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–42 4.6.3 Control Y-Cable Connections – CRS-300 to Modems All tra

Strany 6

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–43 Next, connect and secure the (4X) Quad E1 TMI Data Cables (CEF

Strany 7

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–44 Figure 4-17. Control Y-Cables and EIA-530/-232 Data Ca

Strany 8

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–45 Figure 4-18. Control Y-Cables and Balanced G.703 Data C

Strany 9

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–46 Figure 4-19. Control Y-Cables and Unbalanced G.703 Data

Strany 10

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–47 Figure 4-20. Control Cables and HSSI Data Cables – CRS-

Strany 11

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–48 Figure 4-21. Control Cables and Quad E1 Data Cables – C

Strany 12

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–49 4.7 CDM-700 Modem Connections o Interface Co

Strany 13 - Figures

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM ix A.3.5 Optional EIA-485 Multi-drop Ribbon Cable, (15X) DB-9 Female

Strany 14

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–50 4.7 CDM-700 Modem Connections If adding a modem to an operat

Strany 15

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–51 2. The Traffic CDM-700 must have the same interface cards in

Strany 16

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–52 4.7.5 Ethernet Traffic Data Connections - CRS-300 to Modems T

Strany 17 - PREFACE

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–53 Figure 4-22. Control and Traffic Data Cables Example #1 – CR

Strany 18 - Preface MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–54 Figure 4-23. Control and Traffic Data Cables Example #2 – C

Strany 19 - Low Voltage Directive (LVD)

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–55 Figure 4-24. CDM-700 IP Connections – Wired-thru Example #1

Strany 20 - Limitations of Warranty

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–56 Figure 4-25. CDM-700 IP Connections – Wired-thru Example #2 (

Strany 21 - Exclusive Remedies

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–57 Figure 4-26. CDM-700 IP Connections – Wired-around Example #1

Strany 22 - Online Customer Support

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–58 Figure 4-27. CDM-700 IP Connections – Wired-around Example #2

Strany 23 - Chapter 1. INTRODUCTION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–59 4.8 CDM-710 Modem Connections o Interface C

Strany 24 - Introduction MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM x C.5 Packet Structure ...

Strany 25

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–60 4.8 CDM-710 Modem Connections If adding a modem to an operat

Strany 26 - 1.2 CRS-300 Compatibility

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–61 4.8.3 Control Cable Connections – CRS-300 to Modems The Contr

Strany 27

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–62 Figure 4-28. Control and Data Cables Example #1 – CRS-300 t

Strany 28

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–63 Figure 4-29. Control and Data Cables Example #2 – CRS-300

Strany 29 - 1.4.1 Front Panel

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–64 Notes:

Strany 30 - 1.4.2 Rear Panel

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–65 4.9 CDM-710G Modem Connections o Interfac

Strany 31

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–66 4.9 CDM-710G Modem Connections If adding a modem to an opera

Strany 32

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–67 4.9.3 Control Cable Connections – CRS-300 to Modems The Contr

Strany 33 - SLM-5650/5650A

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–68 Figure 4-30. Control and Data Cables Example #1 – CRS-30

Strany 34

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–69 Figure 4-31. Control and Data Cables Example #2 – CRS-3

Strany 35

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xi Figures Figure 1-1. Typical Redundancy System-Level Block Diagram .

Strany 36

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–70 Notes:

Strany 37

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–71 4.10 SLM-5650/5650A Modem Connections o Co

Strany 38

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–72 4.10 SLM-5650/5650A Modem Connections If adding a modem to an

Strany 39

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–73 • HSSI (HD-50F) connector labeled “J2” on the RMI or “J3” on

Strany 40

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–74 4.10.4 User Data Connections – CRS-300 to User The User’s tra

Strany 41 - 1.6.5 Dimensional Envelopes

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–75 Figure 4-32. Control and Data Cables Example #1 – CRS-300 to

Strany 42

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–76 Figure 4-33. Control and Data Cables Example #2 – CRS-300 to

Strany 43

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–77 Figure 4-34. Control and Data Cables Example #3 – CRS-300

Strany 44

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–78 Figure 4-35. Cabling Example for CRS-350 to SLM-565

Strany 45 - Chapter 2. INSTALLATION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–79 4.11 IF Cable Connections o Single Tr

Strany 46 - Installation MN/CRS300.IOM

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xii Figure 4-2. Control Cable Connection Example for CRS-300 ÆCRS-280L

Strany 47

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–80 4.11 IF Cable Connections There are two different possible IF

Strany 48

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–81 Figure 4-36. IF Cabling Example 1 – Single Transponder C

Strany 49

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–82 4.11.2 Multiple Transponder IF Connections (Using IF Switch)

Strany 50

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–83 Figure 4-37. Multiple Transponder IF Connection Cablin

Strany 51

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–84 Notes:

Strany 52

5–1 Chapter 5. MODEM, RMI/TMI, AND SWITCH CONFIGURATION 5.1 Overview IMPOR TANT In order to avoid damage to the modems and CRS-300 switch, it is impo

Strany 53

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–2 5.2 Modem Configuration 5.2.1 Modem Power Co

Strany 54

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–3 changing configuration settings using the fron

Strany 55

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–4 5.2.4.2.1 CDM-625 Redundancy Configuration wi

Strany 56

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–5 5.2.4.3 Switch to CDM-700, CDM-710, CDM-710G

Strany 57

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xiii Figure A-2. DCE Conversion Cable: EIA-530 to V.35 ...

Strany 58

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–6 5.2.4.4 Switch to SLM-5650/5650A Redundancy C

Strany 59

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–7 Furthermore, in Ethernet Bridge Mode, the para

Strany 60

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–8 5.2.4.5 Switch to CDM-Qx/QxL Redundancy Confi

Strany 61 - CABLES AND CONNECTIONS

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–9 Figure 5-2. CDM-Qx/QxL / CRS-300 EIA-485 Sch

Strany 62

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–10 5.3 RMI Card Configuration Reference IMPORTA

Strany 63

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–11 5.4 TMI Card Configuration Reference The fol

Strany 64

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–12 Table 5-2. CRS-316 Jumper ‘JP1’ Settings Use

Strany 65

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–13 5.4.2 EIA-232/-422, V.35 Interfaces via the

Strany 66

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–14 Table 5-5 illustrates the control signal conf

Strany 67

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–15 5.4.3 HSSI Interfaces via the CRS-336 TMI Fi

Strany 68

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM xiv This page is intentionally blank.

Strany 69

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–16 Table 5-6. CRS-336 Jumper ‘JP1’ Settings Use

Strany 70

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–17 5.4.4 HSSI Interface via the CRS-370 TMI Jum

Strany 71

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–18 5.5 Switch Configuration 5.5.1 Switch Power

Strany 72

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–19 5.5.2 Flash Updating The CRS-300 eliminates t

Strany 73

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–20 3. Download the correct firmware file to thi

Strany 74

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–21 6. Run the Upload utility. The User should f

Strany 75

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–22 To deactivate a modem, see Chapter 7.4.5

Strany 76

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–23 To enable Auto mode: Step Procedure 1 Go to

Strany 77

CRS-300 1:10 Redundancy Switch Revision 16 Modem, RMI/TMI, and Switch Configuration MN/CRS300.IOM 5–24 5.5.3.4.2 Set Restore Holdoff Period The &qu

Strany 78

6–1 Chapter 6. CONNECTOR PINOUTS 6.1 CRS-230 Controller Connectors 6.1.1 IF Switch Control – DB-25M Connector The DB-25M IF Switch

Strany 79

xvPREFACE About this Manual This manual provides installation and operation information for the Comtech EF Data CRS-300 1:10 Redundancy Switch. Thi

Strany 80

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–2 6.1.2 485 Pass-Through – DB-9F Connector Table 6-1 indicates the pi

Strany 81

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–3 6.1.4 System Alarms – DB-25F Connector Table 6-3 indicates the pino

Strany 82 - (CnC) Data Connections

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–4 6.2 TMI User Data Connectors 6.2.1 EIA-232/422/V.35 – DB-25F Conne

Strany 83 - Cable Connection Example

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–5 6.2.2 EIA-232/422/V.35/LVDS – DB-25F Connector (CRS-320/340)

Strany 84

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–6 6.2.3 ASI – BNC Connectors (CRS-325) Table 6-6 indicates the

Strany 85

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–7 6.2.5 Balanced G.703 – DB-15F Connector (CRS-325/330/340)

Strany 86

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–8 6.2.6 Unbalanced G.703 – BNC Connectors (CRS-325/330/340)

Strany 87

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–9 6.2.8 HSSI – HD-50F Connector (CRS-336/370) Table 6-11 is

Strany 88

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–10 6.2.9 10/100/1000 Ethernet – RJ-45F Connector (CRS-316/336)

Strany 89 - Notes 2,3

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–11 6.2.10 Quad E1 – RJ-48F Connectors (CRS-365) Table 6-13 indi

Strany 90

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xvi Conventions and References Cautions and Warnings IMPOR TANT IMPORTANT or NOTE

Strany 91

CRS-300 1:10 Redundancy Switch Revision 16 Connector Pinouts MN/CRS300.IOM 6–12 6.2.11 Quad E1 – DB-9F Connectors (CRS-365D) Table 6-14 and

Strany 92

7–1 Chapter 7. FRONT PANEL OPERATION 7.1 Introduction Modem Status Unit Status Vacuum Fluorescent LED Indicators

Strany 93

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–2 7.1.1 Front Panel Keypad The CRS-300 front panel keypad contain

Strany 94

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–3 7.1.2 Front Panel LED Indicators 7.1.2.1 Unit Status LED Indica

Strany 95

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–4 7.1.2.2 Modem Status LED Indicators The behavior of the six fr

Strany 96 - Emulation Mode

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–5 7.1.3 Front Panel Vacuum Fluorescent Display (VFD) The Front Pan

Strany 97

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–6 7.2 CRS-300 Menu Structure Figure 7-2 shows the menu structure o

Strany 98

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–7 7.3 SELECT (Top-Level) Menu SELECT: CONFIG INFO MONI

Strany 99

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–8 7.4.1 CONFIG: MANUAL MANUAL SELECT: BRIDGE:02 BACKUP:02 Th

Strany 100 - MPORTANT

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–9 7.4.3 CONFIG: OPTIONS OPTIONS: PRIORITY HOLDOFFS AL

Strany 101

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xvii EN55024 - 1998 Compliance This equipment meets the EMC/immunity characteristic

Strany 102

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–10 CONFIG: OPTIONS Æ ALARM-MASK If ALARM-MASK is selected: ALARM

Strany 103

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–11 7.4.4 CONFIG: REMOTE SELECT REMOTE CONTROL: LOCAL REMOTE (PR

Strany 104

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–12 EDIT SWITCH BUS ADDRESS: 3000 (PRESS ENTER) The value

Strany 105

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–13 • If desired, the User can go to Manual mode, switchover the a

Strany 106

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–14 7.5.5 INFO: REMCONT (Remote Control Info) REM CNTL: ON R

Strany 107

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–15 7.6.2 MONITOR: SW-ALARM The following are examples of possible

Strany 108

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–16 The three-letter instruction code is indicated also to assist de

Strany 109

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–17 ► For the CDM-Qx modem, the code is the decimal number indicati

Strany 110

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–18 7.6.3 MONITOR: STORED-EVENTS STORED EVENTS: VIEW CLEAR-ALL (

Strany 111

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–19 7.7 SELECT: STORE/LD (Store or Load Configuration) STORE/LOAD

Strany 113

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xviii Warranty Policy Comtech EF Data products are warranted against defects in mat

Strany 114

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–20 7.8 SELECT: UTILITY UTILITY: SET-RTC DISPLAY SWITCH-ID TE

Strany 115

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–21 7.8.4 UTILITY: TEST This is an excellent method to test the wh

Strany 116

CRS-300 1:10 Redundancy Switch Revision 16 Front Panel Operation MN/CRS300.IOM 7–22 Notes:

Strany 117

A-1 Appendix A. CABLE DRAWINGS A.1 Introduction This appendix contains drawings of cables used with the CRS-300. These cables are divided into thre

Strany 118

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-2 A.2.1 EIA-530 to EIA-422 Data Cable Figure A-1 shows the cable drawing

Strany 119

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-3 A.2.2 EIA-530 to V.35 Data Cable Figure A-2 shows the cable drawing fo

Strany 120

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-4 A.2.3 Switch Programming Cable Figure A-3 shows the cable required for

Strany 121

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-5 A.3 Control Cables App. A FIG CEFD P/N DESCRIPTION USED WITH CRS

Strany 122

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-6 A.3.1 Control Cable for CDM-625 Figure A-4 shows the control cable that

Strany 123

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-7 A.3.2 Standard EIA-485 Multi-drop Shielded Cable, (15X) DB-9 Female Fig

Strany 124

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xix The warranty excludes any responsibility by Comtech EF Data Corporation for inc

Strany 125

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-8 A.3.3 EIA-485 Cable Termination, (15X) DB-9 Male Figure A-6 shows the E

Strany 126

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-9 A.3.4 EIA-485 Null Modem Cable, DB-9 Male Figure A-7 shows the EIA-485

Strany 127 - NETWORK CONFIGURATIONS

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-10 A.3.5 Optional EIA-485 Multi-drop Ribbon Cable, (15X) DB-9 Female Figu

Strany 128

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-11 A.3.6 Control ‘Y’ Cable for CDM-Qx and CDM-QxL with CnC® Figure A-9 sh

Strany 129

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-12 A.3.7 Control Cable for CDM-700, CDM-710 Figure A-10 shows the control

Strany 130

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-13 A.3.8 Control Cable for SLM-5650/5650A Figure A-11 shows the control c

Strany 131

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-14 A.3.9 Control ‘Y’ Cable for SLM-5650/5650A to CRS-300 Figure A-12 show

Strany 132

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-15 A.4 Control / IF / Data Cables & Accessories App. A FIG CEFD P/N

Strany 133 - IMPORTANT

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-16 App. A FIG CEFD P/N DESCRIPTION USED WITH CRS-300 Æ … Chp. 4 FIG USE

Strany 134

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-17 A.4.1 EIA-232/422, EIA-530 Control and Data Cable, DB-25 Figure A-13 s

Strany 135

CRS-300 1:10 Redundancy Switch Revision 16 Preface MN/CRS300.IOM xx Customer Support IMPORTANT Refer to the Warranty Policy, p. xviii, for informati

Strany 136

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-18 A.4.2 Balanced G.703 Data Cable for CDM-570/570L, DB-15 Figure A-14 sh

Strany 137

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-19 A.4.3 Balanced G.703 Data Cable, DB-15 Figure A-15 shows the data cabl

Strany 138

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-20 A.4.4 Audio Data Cable, DB-9 Figure A-16 shows the cable used for hand

Strany 139 - 4.11 IF Cable Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-21 A.4.5 Balanced G.703 Data Cable for CDM-625 Figure A-17 shows the cabl

Strany 140 - 4.11 IF Cable Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-22 A.4.6 Quad E1 ‘Y’ Data Cable for CDM-625 Figure A-18 shows the cable a

Strany 141

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-23 A.4.7 ASI / Balanced G.703 / IF Cable, BNC 75Ω Figure A-19 shows the 7

Strany 142

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-24 A.4.8 Overhead Data Cable for CDM-625 Figure A-20 shows the multi-purp

Strany 143

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-25 A.4.9 HSSI Data Cable, HD-50 Male Figure A-21 shows the HSSI data cabl

Strany 144

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-26 A.4.10 Quad E1 Data Cable for CDM-Qx / QxL Figure A-22 shows the cable

Strany 145 - IMPOR TANT

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-27 A.4.11 Quad E1 / Gigabit Ethernet RJ-48 Connector Cable Figure A-23 sh

Strany 146 - 5.2.2.1 Flash Updating

1–1 Chapter 1. INTRODUCTION 1.1 Overview This chapter provides an overview, description and specifications for the CRS-300 1:10 Redundancy Switch and

Strany 147

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-28 A.4.12 G.703 Data Cable for CDM-700 Figure A-24 shows the cable used t

Strany 148

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-29 A.4.13 G.703 Data Cable for CDM-700 Figure A-25 shows the cable used t

Strany 149

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-30 A.4.14 IF Cable, BNC 50Ω Figure A-26 shows the 50Ω BNC cable used for

Strany 150 - Processor (NP) Interface

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-31 A.4.15 Ethernet Data Cable for CDM-625 Figure A-27 shows the Ethernet

Strany 151

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-32 A.4.16 Multi-drop CnC® Plus Shielded Data Cable for CDM-625, (11X) D

Strany 152 - Slot 4 Demod

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-33 A.4.17 Quad E1 Data Cable for CDM-625, DB-9 Figure A-29 shows the DB-9

Strany 153

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-34 A.4.18 Quad E1 Data Adapter Cable for CDM-625 Figure A-30 shows the d

Strany 154

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-35 A.4.19 Quad E1 Data Adapter Cable for CDM-625 Figure A-31 shows the d

Strany 155 - Tables 5-2 throu

CRS-300 1:10 Redundancy Switch Revision 16 Cable Drawings MN/CRS300.IOM A-36 A.4.20 T1/E1 Adapter for CDM-570/570L, -600/600L Figure A-32 shows the

Strany 156

B–1 Appendix B. ADDRESSING SCHEME INFORMATION B.1 Introduction to Addressing A CRS-300 1:10 Redundancy Switch provides 1:10 redundancy; that is, it

Strany 157

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–2 The CRS-300 1:10 Redundancy Switch (referred to throughout this manual as

Strany 158 - Rev. D and later versions

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–2 B.2 Switch Addresses The permitted Switch remote control

Strany 159

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–3 Figure B-1. CRS-300 Addressing Scheme Example: Exter

Strany 160

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–4 Figure B-2. CRS-300 Addressing Scheme Example: Externa

Strany 161 - CA and TA

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–5 Figure B-3. CRS-300 Addressing Scheme E

Strany 162 - 5.5.1 Switch Power

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–6 Figure B-4. CRS-300 Addres

Strany 163 - 5.5.2 Flash Updating

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–7 Figure B-5. CRS-300 Addres

Strany 164

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–8 Figure B-6. CRS-300 Ad

Strany 165 - 5.5.2.1.1 Flash Update Help

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–9 Figure B-7. CRS-300 Addressing Scheme E

Strany 166

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–10 This page is intentionally blank.

Strany 167 - 5.5.3.4 Set Holdoff Period

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–11 B.3.1 Setting Up Modems • Local Modem m, wher

Strany 168 - 5.5.3.5 Set Alarm Masking

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–3 NOTE the CRS-300). For detailed information on remote addressing sch

Strany 169

CRS-300 1:10 Redundancy Switch Revision 16 Addressing Scheme Information MN/CRS300.IOM B–12 B.3.2 Setting Up Transceivers IMPORTANT Config

Strany 170

C–1 Appendix C. REMOTE CONTROL C.1 Overview This appendix describes the protocol and message command set for remote monitor and control of the CRS

Strany 171

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–2 C.3 EIA-232 This is a much simpler configuration in which the Controlle

Strany 172

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–3 o To a local BUC or transceiver connected to a local modem; o To a dis

Strany 173

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–4 modem protocol and the installed options. Consult the appropriate modem

Strany 174 - ASI connectors

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–5 C.5.5 Instruction Code Qualifier This single character further qualifie

Strany 175

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–6 C.5.6 Optional Message Arguments Arguments are not required for all mes

Strany 176 - Unbalanced G.703 connectors

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–7 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 177

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–8 Parameter Type Command (Code and qualifier) Arguments for Command or Res

Strany 178

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–9 Parameter Type Command (Code and qualifier) Arguments for Command or Res

Strany 179 - Quad E1 connectors

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–4 1.2 CRS-300 Compatibility Table 1-1 shows the Comtech EF Data modems tha

Strany 180

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–10 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 181 - OPERATION

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–11 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 182

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–12 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 183

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–13 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 184

CRS-300 1:10 Redundancy Switch Revision 16 Remote Control MN/CRS300.IOM C–14 Parameter Type Command (Code and qualifier) Arguments for Command or Re

Strany 185 - 7.1.4 Opening Screen

METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01094

Strany 186 - 7.2 CRS-300 Menu Structure

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Strany 187

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–5 1.3 System-Level Block Diagram Figure 1-1 shows the system-level block d

Strany 188 - 7.4.1 CONFIG: MANUAL

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–6 1.3.1 CRS-280/280L Functional Schematic Figure 1-2 provides an operatio

Strany 189 - 7.4.3 CONFIG: OPTIONS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–7 1.4 Description of CRS-300 Features 1.4.1 Front Panel Figure 1-3 illust

Strany 190

Copyright © Comtech EF Data, 2010. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Strany 191 - 7.4.4 CONFIG: REMOTE

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–8 NOTE 1.4.2 Rear Panel Figure 1-4 shows the back panel of the CRS-30

Strany 192

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–9 CDM-625 Modem Data Type TMI Type RMI Type EIA-422, V.35 CRS-316 Notes 5

Strany 193 - 7.5.4 INFO: IF-SWITCH

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–10 1.4.3.2 TMI Cards: CDM-570/570L, -600/600L, -625 Figure 1-6. CRS-320 TM

Strany 194 - 7.6.1 MONITOR: STATUS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–11 1.4.4 Modem Interface Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/56

Strany 195 - 7.6.2 MONITOR: SW-ALARM

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–12 1.4.4.1 RMI Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/5650A Figure

Strany 196

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–13 1.4.4.2 TMI Cards: CDM-Qx/QxL, -700, -710, -710G, SLM-5650/5650A Figure

Strany 197

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–14 1.4.5 CRS-300 System Controller and Power Supply Card Assembli

Strany 198 - 7.6.5 MONITOR: IO

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–15 Figure 1-24. CRS-350 ESC Switch – Front Panel As explained in detail in

Strany 199 - 7.7.2 STORE/LD: LOAD

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–16 1.6 Summary of Specifications 1.6.1 CRS-300 Specifications Characteris

Strany 200 - 7.8.3 UTILITY: SWITCH-ID

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–17 1.6.2 Modem vs. Terrestrial User Data Interface Specifications Modem T

Strany 201 - 7.8.5 UTILITY: RELAY

This page is intentionally blank.

Strany 202

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–18 1.6.3 CRS-280 and CRS-280L Specifications Characteristic Requirement C

Strany 203 - Appendix A. CABLE DRAWINGS

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–19 11.94 (30.3) 17.00 (43.2) 12.68 (322) CLR ENT UNIT STATUSUNIT STATUS UN

Strany 204

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–20 Figure 1-29. CRS-280 (70/140 MHz) Dimensional Envelope

Strany 205

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–21 17.00(43.18)13.18(33.48)13.92(35.36)6.96(17.68)19.00(48.26) Figure 1-30.

Strany 206

CRS-300 1:10 Redundancy Switch Revision 16 Introduction MN/CRS300.IOM 1–22 Notes:

Strany 207 - A.3 Control Cables

2–1 Chapter 2. INSTALLATION 2.1 Unpacking and Inspection Step Procedure 1 Inspect shipping containers for damage. 2 If shipping containers are damag

Strany 208

CRS-300 1:10 Redundancy Switch Revision 16 Installation MN/CRS300.IOM 2–2 or on top of the rack. If using the CRS-280L, refer also to the associate

Strany 209

3–1 Chapter 3. ETHERNET NETWORK CONFIGURATIONS 3.1 Introduction For operations requiring Ethernet-based terrestrial data handling, it is important t

Strany 210

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–2 3.3 Ethernet Configuration Examples This section exp

Strany 211

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–3 3.3.2 Ethernet Redundancy with CRS-300 After the cus

Strany 212

iii Table of Contents TABLE OF CONTENTS ...

Strany 213

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–4 3.3.3 Hub-to-Hub with Standard Traffic using Switche

Strany 214

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–5 This page is intentionally blank

Strany 215

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–6 3.3.4 Hub-to-Hub with Standard Traffic using Routers F

Strany 216

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–7 Figure 3-5. Wired-thru for Hub-to-Hub with Standard Tr

Strany 217

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–8 3.3.5 Hub-to-Remotes with Standard Traffic using Route

Strany 218 - Chp. 4 FIG USED FOR (TYPE)

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–9 Figure 3-8. Wired-thru for Hub-to-Remotes with Standar

Strany 219

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–10 3.3.6 Hub-to-Remotes, Split-path Traffic using Router

Strany 220

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–11 Figure 3-11. Wired-thru for Point-to-Multipoint wit

Strany 221

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–12 3.3.7 Hub-to-Remotes, Split-path Traffic using Switch

Strany 222

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–13 Figure 3-14. Wired-thru, Hub-to-Remotes, Split-path T

Strany 223

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM iv 1.4 Description of CRS-300 Features ...

Strany 224

CRS-300 1:10 Redundancy Switch Revision 16 Ethernet Network Configurations MN/CRS300.IOM 3–14 Notes:

Strany 225

4–1 Chapter 4. CABLES AND CONNECTIONS 4.1 Overview All cables for connecting the CRS-300 1:10 Redundancy Switch to the modems or within the

Strany 226

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–2 Notes:

Strany 227

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–3 4.2 Switch-to-Switch Connections o CRS-300 to CR

Strany 228

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–4 4.2 Switch-to-Switch Connections If the User’s redundancy syst

Strany 229

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–5 Figure 4-1. Control Cable Connection Example for CRS-300

Strany 230 - CDM-700 Modem Connections

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–6 Figure 4-2. Control Cable Connection Example for CRS-300

Strany 231

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–7 Figure 4-3. Control Cable Connection Example for CRS-300

Strany 232 - A.4.14 IF Cable, BNC 50Ω

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–8 Figure 4-4. Control Cable Connection Example for CRS-300 Æ CR

Strany 233

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–9 Figure 4-5. Control Cable Connection Example for CRS-300 Æ CRS

Strany 234 - A.4.16 Multi-drop CnC

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM v 4.2.2 CRS-300 to CRS-350 Connection ...

Strany 235

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–10 Notes:

Strany 236

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–11 4.3 CDM-570/570L Modem Connections o Co

Strany 237

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–12 4.3 CDM-570/570L Modem Connections If adding a modem to an op

Strany 238

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–13 Figure 4-6. Data Cable Connection Example – CRS-300 to CDM-5

Strany 239 - SCHEME INFORMATION

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–14 Notes:

Strany 240 - B.2 Switch Addresses

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–15 4.4 CDM-600/600L Modem Connections o Contro

Strany 241

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–16 4.4 CDM-600/600L Modem Connections If adding a modem to an op

Strany 242

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–17 Figure 4-7. Data Cable Connection Example – CRS-300 to CDM-6

Strany 243 - 1.6.2 or later

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–18 4.4.2 User Data Connections – CRS-300 to User The User’s tra

Strany 244

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–19 Figure 4-8. Cabling Example for CRS-350 to CDM-600/60

Strany 245

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM vi 4.7.5.2 Wired-around Connections ...

Strany 246

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–20 Notes:

Strany 247

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–21 4.5 CDM-625 Modem Connections o RMI/TMI Limita

Strany 248

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–22 4.5 CDM-625 Modem Connections If adding a modem to an operati

Strany 249 - B.3.1 Setting Up Modems

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–23 Figure 4-9. CDM-625 to CDM-625 CnC® Cable Connection Exampl

Strany 250 - B.4 M&C Applications

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–24 4.5.3 Control and Data Connections – CRS-300 to Modem Table 4

Strany 251 - Appendix C. REMOTE CONTROL

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–25 For specific details regarding the CA/WR0066 cable’s use as a

Strany 252 - C.4 Basic Protocol

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–26 • DB-9F connector labeled “1:1 Control” on the Traffic CDM-62

Strany 253 - C.5.2 Target Address

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–27 4.5.3.4 EIA-422 Data Connections If EIA-422 is the driving t

Strany 254 - C.5.4 Instruction Code

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–28 Then, connect and secure the Control/Data Cable CA/WR0066 (for

Strany 255

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–29 4.5.3.8 Ethernet Data Connections IMPORTANT1. When using the

Strany 256 - C.5.7 End of Packet

CRS-300 1:10 Redundancy Switch Revision 16 Table of Contents MN/CRS300.IOM vii 5.4 TMI Card Configuration Reference ...

Strany 257

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–30 NO TE 1. Where the traffic data type is Ethernet, the User c

Strany 258

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–31 Figure 4-10. CRS-300 to CDM-

Strany 259

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–32 Figure 4-11. CRS-300 to CDM-625 Cable Connection Example – G.

Strany 260

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–33 Figure 4-12. C

Strany 261

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–34 Figure 4-13. C

Strany 262

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–35 4.5.4 Data Connections – CRS-300 to User The User’s traffic

Strany 263

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–36 The choices from this display are: • Normal: CDM-625 • Emula

Strany 264

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–37 Figure 4-15. Data Cables - CRS-300 to CDM-625 (CDM-600/600L E

Strany 265

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–38 Notes:

Strany 266 - • 333 • 2161 FAX

CRS-300 1:10 Redundancy Switch Revision 16 Cables and Connections MN/CRS300.IOM 4–39 4.6 CDM-Qx/QxL Modem Connections o RMI/TMI Lim

Komentáře k této Příručce

Žádné komentáře