Comtech EF Data KPA-040 Specifikace Strana 115

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 128
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 114
KPA Ku-Band Indoor Solid-State Power Amplifier Revision 1
Appendix C MN/KPA.IOM
C–19
Equipment Type Retrieve Equipment Type:
Confirmation:
<DEV/RET_'cr'
>DEV/RET_xxxxxxx yyyyy'cr''lf']
Where: xxxxxxx = Model No.
yyyyy = Software Version
Example: >DEV/RET_K080-4045-I SW_1.02
Equipment Type is a command that retrieves the model number
and software version of the equipment. The information cannot be
changed by command.
Application
Identification
Application ID:
Confirmation:
Retrieve ID:
Confirmation:
<DEV/AID_xxxxxxx…xxxxx'cr'
>DEV/AID_'cr'xxxxxxxxxxxxxxxxxxxxxxxx'cr'
xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf']
<DEV/AID_'cr'
>DEV/AID_'cr'xxxxxxxxxxxxxxxxxxxxxxxx'cr'
xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf'
Where: XXXXXXX …XXXXX = Message, maximum 48
characters
The Application Identification (AID) command allows a free form
message to be created. It is intended to identify the satellite
transponder, beam, destination or other aspects of the application
that may be significant to operations. The message length
corresponds to capability of the LCD and is 48 characters in total.
The second line begins at character 25; therefore, blanks must be
used after line 1 information in order to space to line 2. A carriage
return ends the command. Trailing blanks will be generated to fill
the LCD field. The AID display will alternate with the Equipment
type display by use of the clear function key on the front panel. The
default is “AID MESSAGE.”
Local/Remote Entry
Mode Status
KPA-040
Local/Remote Control:
Confirmation:
Retrieve Local/Remote
Status:
Confirmation:
<DEV/LRS_x'cr'
>DEV/LRS_x'cr''lf']
<DEV/LRS_'cr'
>DEV/LRS_x'cr''lf']
Where: x= 0 for Local or 1 for Remote
Zobrazit stránku 114