MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–22
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Sets or returns the time, indicating the time from midnight, in the form
hhmmss where:
hh=hours, between 00 and 23
mm=minutes, between 00 and 59
ss=seconds, between 00 and 59
Example: TIM=231259 would be 23 hours, 12 minutes and 59 seconds
TIM?
TIM *
(same format as
command
arguments)
of unread
Stored Alarms
Returns the number of Stored Events that remain unread, in the form xx.
Example reply: TNA=18
(see Description of
Arguments for
details)
Change
Returns the status of the Terminal Status in the form x, where:
x=0 (no change in status) or 1 (change in status)
(see Description of
Arguments for
details)
Reference Fault
Logic
Sets or returns enabling/disabling the software monitoring of the external
reference source in the form x, where:
x=0 (Ext Reference not monitored) or 1 (Ext Reference is monitored and
the lock state reported)
Note: If enabled and no source is present, a fault will be reported.
XRF?
(see Description of
Arguments for
details)