MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–8
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Recovery State
Sets or returns Automatic Fault Recovery on a BUC in the form x, where:
x=0 (Disabled) or 1 (Enabled)
AFR?
AFR*
(same format as
command
arguments)
numeric
Sets or returns a valid attenuation level, in dB, at 0.25dB step size as
factory default.
ATT?
ATT*
ATT!
Alarms
Instructs the slave to clear all Stored Events.
This command takes no arguments.
COMM I/O
Returns the Concise AUX COMM I/O of the MBT-4000B base unit, in the
form nabcd where:
n=1 (AUX COMM)
a=12V (0=Off, 1=On)
b=IOA (O=logic low [voltage input < 0.5],
1=logic high [voltage input > 2.7 vdc)
c=IOB (O=logic low [voltage input < 0.5],
1=logic high [voltage input >2.7 vdc]
d=Reserved (Always zero)
Example: <0001/CAI?n{cr}
>0001?CAI=nabcd{cr}{lf}
CAI?
CAI*
(see Description of
Arguments for
details)