MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–21
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Returns the unit’s 9 digit serial number. Slave returns its S/N, in the form
xxxxxxxxx.
(see Description of
Arguments for
details)
Utility Status
alphanumeric
Returns the utility status of the MBT-4000B base unit..
Example:
<0001/RUS={cr}
>0001/RUS={cr}{lf}
ADR=0001{cr}
BDR=9600{cr}{lf}
(see Description of
Arguments for
details)
Rate
Sets or returns the remote baud rate as follows: in the form xxxx, where:
9600=9600 baud
SBR?
SBR!
(same format as
command
Status
Returns the status of the Summary Fault Relay in the form x, where:
x=0 (OK) or 1 (FLT)
(see Description of
Arguments for
details)
Sets or returns the Physical Address of the MBT-4000B base unit in the
form xxxx, where:
xxxx=an address from 0001 to 9999, resolution=0001
SPA?
SPA!
(same format as
command
arguments)
BUC
Sets or returns the Slope adjust level in the form x.x, where:
x.x=valid number from 0.0 to 1.0, resolution=0.1
SSA?
SSA*
SSA!
(same format as
command
arguments)
Switch
alphanumeric
Sets the switches dedicated to Slot 1 or 2, and sets them to either Port A
or Port B in the form xy, where:
x =1 (Slot 1) or 2 (Slot 2)
y=A (Switched to Converter on MBT_A) or B (Switched to Converter on
MBT_B)
SSW=xy
(same format as
command
arguments)