SNM-1000 Node Control Modem Revision 3
Installation MN/SNM1000.IOM
2–6
2.3.2 Fault Connector and Pinouts (J7)
The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts, ratings 1A maximum at 24 VDC, 0.5A at 120 VAC, are
Modulator, Demodulator, and Common Equipment.
The fault interface connection is a 9-pin subminiature female D connector (J7) located on
the rear panel of the modem. Screw locks are provided for mechanical security on the
mating connector. Refer to Table 2-2 for pinout information.
Table 2-2. Fault Connector and Pinouts (J7)
Pin # Signal Function Name
1 Common equipment is not faulted NO
2 COM
3 Common equipment is faulted NC
4 Modulator is not faulted NO
5 COM
6 Modulator is faulted NC
7 Demodulator is not faulted NO
8 COM
9 Demodulator is faulted NC
Note: A connection between the common (COM) and normally open (NO)
contacts indicates no fault.
Refer to Chapter 5 for a discussion of monitored faults. To obtain a system summary
fault, connect all the Form C contacts in parallel.