LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–36
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Change
Indicates if there has been a change in the configuration since the last time a command was issued, in the form
x, where:
0 = no status change
1 = there has been a status change.
A status change is defined as any time a parameter is changed, such as when command that changes a value is
successfully executed. A status change also results when there is a redundant switchover, or a fault condition.
A query does not set the status change flag. The status change flag is cleared after being read.
Example: <1/TSC?’cr’
>0001/TSC=0’cr’’lf’
(See Description of
Arguments)
Reference Mute
O
numeric
Sets or returns the external reference mute state in the form x, where:
0 = Disable
1 = Enable (see Note)
Note: To enable this command, the internal reference oscillator option must be installed; otherwise, a mode
error will result. A hardware mute condition generated by the XRM mute is one of the conditions that can cause
the MUT command to return MUT=2.
When enabled, the unit will mute if an external reference oscillator is not detected.
XRM?
MSK*
(See Description of
Arguments)