LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC) MN-LPOD
Serial-based Remote Product Management Revision 10
5–15
Parameter Type
(Instruction
Code and
for Command
or Response
Description of Arguments
(Note that all arguments are printable ASCII characters)
Command
(Target to
(Instruction
Code and
Response to Query
(Target to
Controller)
Current
Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.
Default value: 000.0
The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current window
setting (see LCW command).
Note: this command will return a mode error if the LNB current source output has not been enabled first (see
LCS command).
Example: <1/CLC=’cr’
>0001/CLC=’cr’’lf’
The CLC query will return the value that was stored during the LNB current calibration.
Example: <1/CLC?’cr’
>0001/CLC=xxx.x where xxx.x is the calibrated LNB current value in mA.
CLC?
CLC*
(See Description of
Arguments)
Log
Clears the statistics log entries. This command takes no arguments.
Example:
<1/CSL=1’cr’
CSL?
CSL*
Status
E
Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:
aaaa = Remote Unit Address
bbbbb = Remote Baud Rate
ccc = Reference oscillator tuning voltage DAC value (see Note)
Note: ccc is only present if a reference oscillator is installed.
Example:
<1/CUS?’cr’
>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’
(See Description of
Arguments)