UT-4500 Series Up Converter Installation and Operation Manual Part Number MN/UT4500.IOM Revision 2 IMPORTANT NOTE: The information contained in th
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 iv 1.7 Prime Power Switch...
UT4500 Series Up Converter MN/UT4500.IOM Theory of Operation Revision 2 82 The "Daisy Chain" configuration is designed to chain the IF inp
UT4500 Series Up Converter MN/UT4500.IOM Theory of Operation Revision 2 83 5/10 MHzREF. OSC.IF INPUT(70 or 140 MHz)RF OUTPUT(14000-14500 MHz)MONITOR
UT4500 Series Up Converter MN/UT4500.IOM Theory of Operation Revision 2 84 6.3 MONITOR & CONTROL The Monitor & Control Assembly is designed
85 Chapter 7. Maintenance and Troubleshooting 7.1 OVERVIEW This appendix is intended to provide procedures to assist operator and maintenance perso
UT4500 Series Up Converter MN/UT4500.IOM Maintenance and Troubleshooting Revision 2 86 PowerSupplyReferenceOscillatorFineStepModuleSumLoopModuleMon
UT4500 Series Up Converter MN/UT4500.IOM Maintenance and Troubleshooting Revision 2 87 7.2.2 TROUBLESHOOTING Converter operating problems can be ide
UT4500 Series Up Converter MN/UT4500.IOM Maintenance and Troubleshooting Revision 2 88 7.2.3.3 RF CONVERTER MODULE IFLO LOCK DETECT: A fault (“FT”)
UT4500 Series Up Converter MN/UT4500.IOM Maintenance and Troubleshooting Revision 2 89 7.2.4 CONVERTER I/O MODULES The Converter I/O Modules (IOM, o
UT4500 Series Up Converter MN/UT4500.IOM Maintenance and Troubleshooting Revision 2 90 NOTES:
91 Index A About this Manual... ix Access Methods ...57 Addresses ...
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 v 4.4.1 Initial Configuration...
UT4500 Series Up Converter MN/UT4500.IOM Index Revision 2 92 O Offset Adjustment...52 Operation...
METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281
2114 West 7th Street Tempe Arizona 85281 USA 480 • 333 • 2200 Phone 480 • 333 • 2161 FAX
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 vi 5.8 Converter Remote Command Summary...
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 vii Figures Figure 1. Front Panel (Model UT-4505 shown) ...
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 viii Tables Table 1. UT-4505 C-Band Up Converter Specifications...
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 ix ABOUT THIS MANUAL This manual provides installation and operation information for the
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 x REPORTING COMMENTS OR SUGGESTIONS CONCERNING THIS MANUAL Comments and suggestions rega
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 xi SAFETY COMPLIANCE EN 60950 Applicable testing is routinely performed as a condition
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 xii WARRANTY POLICY This Comtech EF Data product is warranted against defects in materia
1 Chapter 1. Introduction UT-4500 Series Up Converter 1.1 OVERVIEW This manual provides instructions on the installation, operation and maintenance
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 2 1.2 FUNCTIONAL DESCRIPTION The UT-4500 Series Up Converters are designed for use
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 3 5/1 0 MHzREF. OSC.IF INPUT(70 or 140 MH z)RF OUTPUT(14000-14500 MHz)MON ITOR&
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 4 1.3 SPECIFICATIONS Note: Contact CEFD for specific requirements. Table 1. UT-450
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 5 Characteristic Specification Group Delay Linear Group Delay Parabolic Delay G
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 6 Table 2. UT-4505/E/F/G/H/J/X Up Converter Specifications Characteristic Specifi
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 7 Characteristic Specification External Ref. Input, either 5 or 10 MHz Option @ +3
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 8 Table 3. UT-4505I/M Up Converter Specifications Characteristic Specification Fr
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 9 Characteristic Specification Phase Noise 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 10 Table 4. UT-4514 and UT-4514/C/D/E/F Up Converter Specifications Characteristic
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 11 Characteristic Specification Phase Noise 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
Filename: T_ERRATA 1 Errata A Comtech EF Data Documentation Update Subject: Revised 5.6.4.7 Packed Configuration Status Date: December 16, 2005
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 12 Table 5. UT-4518 and UT-4518/E Up Converter Specifications Characteristic Spec
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 13 Characteristic Specification Phase Noise 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 14 1.3.1 DIMENSIONAL ENVELOPE (UT-4500) Dimensions are shown in both inches and cen
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 15 1.4 PHYSICAL CONFIGURATION Figure 5 is a top view layout of a UT-4500 Series Up
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 16 1.5 FRONT PANEL DISPLAY The front panel display is a two line, 24-character, LCD
UT4500 Series Up Converter MN/UT4500.IOM Introduction Revision 2 17 NOTES:
19 Chapter 2. Installation 2.1 UNPACKING AND INSPECTION Inspect the shipping container for damage. If the shipping containers are damaged, keep them
UT4500 Series Up Converter MN/UT4500.IOM Installation Revision 2 20 2.4 CABLE CONNECTIONS Connect the signal cables to the connectors on the rear pa
UT4500 Series Up Converter MN/UT4500.IOM Installation Revision 2 21 2.4.2 EIA-485/EIA-232 INTERFACE (COM 1), CONNECTOR J1 The EIA-485/EIA-232 Inter
Filename: T_ERRATA 2
UT4500 Series Up Converter MN/UT4500.IOM Installation Revision 2 22 2.4.3 HIGH SPEED BUS (HSB), CONNECTOR J3 The High-Speed Bus connector, J3, is 25
UT4500 Series Up Converter MN/UT4500.IOM Installation Revision 2 23 PowerSupplyReferenceOscillatorFineStepModuleSumLoopModuleMonitor & Control A
UT4500 Series Up Converter MN/UT4500.IOM Installation Revision 2 24 J5RFIFJ3 HSBJ4IOM-XXIFOUTPUTRFINPUTNOCONNECTION Figure 7. Non-Redundant Convert
25 Chapter 3. System Operation 3.1 OVERVIEW This chapter contains instructions for operating the converter. Illustrations of the front and rear pane
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 26 Table 12. Operating Functions – Front Panel Item Reference Designation Fu
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 27 3.2 SWITCHING POWER ON Before turning the Prime Power Switch to the ON posi
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 28 LEGENDDISPLAYKEY-PADENTCLR---------SELECT-----------MONITOR-STATUS-MENU-----
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 29 FREQ= 14XXX.XXX-MHz-----ATTN=-10.00-DB---Tx=OFF-ENTER---------SELECT--------
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 30 ENTER---------SELECT-------------CONFIGURATION-MENU----ENTRY-MODE-=-REMOTE--
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 31 ENTER---------SELECT-------------CONFIGURATION-MENU----ENTRY-MODE-=-REMOTE--
Filename: T_ERRATA 1 Errata B Comtech EF Data Documentation Update Subject: Added Dual IF Rack Mount Converters Date: August 28, 2006 Document: U
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 32 ENTER---------SELECT--------------PRE-SELECT-MENU-----PROGRAM-PRE-SELECT-XX-
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 33 ENTER---------SELECT------------CURRENT-FAULTS-MENU--SYNTH-FAULTS:-SUM-LD=OK
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 34 ENTER---------SELECT----------UTILITY-FUNCTIONS-MENU--DISPLAY-CONTRAST-=-XX-
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 35 3.3.1 CONVERTER COMMANDS The converter commands are in a tree structured men
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 36 3.3.2 CONFIGURATION FUNCTIONS MENU The Configuration Functions are as follow
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 37 3.3.3.2 CONFIGURE CONVERTER TO PRE-SELECT This command allows the local oper
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 38 3.3.5.3 SYNTHESIZER FAULTS Displays the synthesizer faults: Sum Loop Dete
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 39 3.3.7 UTILITY FUNCTION MENU The local operator can input commands to the fol
UT4500 Series Up Converter MN/UT4500.IOM System Operation Revision 2 40 NOTES:
41 Chapter 4. Redundant System Operation 4.1 OVERVIEW The Comtech EF Data UT-4500 Series Up Converters are configured for redundant system operatio
Filename: T_ERRATA 2 Dual IF Rack Mount Converters Comtech EF Data offers converters with the ability to switch the output IF frequency (Downconv
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 42 4.2 BACKUP CONVERTER The "Daisy Chain" terminates in the backup conv
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 43 4.3 REDUNDANT CONFIGURATIONS Comtech EF Data UT-4500 Series Up Converters can
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 44 LP OUTLP IN RFJ9J5IFJ4IOM -XXLP OUTJ3 HSBJ4 J6 J8IFJ5LP INJ7RFOUTPUTRFIFINPUT
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 45 IF InUp Converter - IOM(Backup Unit)Up Converter - TSEQM(On line)RF OutRF OutI
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 46 J9J7J5RFJ5IFJ4IOM-XXLP OUTLP INJ3 HSBLP OUTLP INJ4 J6J8RFIFIFINPUT #1
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 47 BACKUP CONVERTER (BU)CONVERTER No. 1CONVERTER No. 2CONVERTER No. NRFOUTPUT#1RF
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 48 RFOUTPUT#3RFOUTPUT#NRFOUTPUT#4RFOUTPUT#2RFOUTPUT#1IFINPUT#NIFINPUT#1IFINPUT#2
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 49 4.4 REDUNDANT SYSTEM CONFIGURATION 4.4.1 INITIAL CONFIGURATION Redundant syste
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 50 4.4.2 AUTOMATIC CONFIGURATION VERIFICATION The backup converter has a menu tha
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 51 Figure 31 depicts the front panel displays after power has been turned off on
Copyright © Comtech EF Data, 2001. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 52 4.4.3 MANUAL CONFIGURATION/VERIFICATION Figure 32 shows the system with conver
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 53 Figure 33 shows the front panel displays after the backup has forced converter
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 54 4.4.4 OFFSET ADJUSTMENT The offset is used to compensate for cable and switch
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 55 To remove a “Backup” converter for repair the following procedure must be use
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 56 NOTES:
57 Chapter 5. Remote Control 5.1 GENERAL Each Comtech EF Data series Up Converter can be remotely controlled through a serial port. Primary (chain
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 58 5.2.2 BAUD RATE The default serial port Baud Rate is 9600. Baud rates of 1200
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 59 5.3 ACCESS METHODS Converters may be accessed directly by using a physical add
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 60 5.3.2.2 EIA-232 To control by using the EIA-232 interface, one EIA-232 port on
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 61 5.5 MESSAGE STRUCTURE The structure of either a Command , Response or Error Me
UT4500 Series Up Converter MN/UT4500.IOM Preface Revision 2 ii CUSTOMER SUPPORT Contact the Comtech EF Data Customer Support Department for: Pro
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 62 5.5.5 ERROR RESPONSE If a converter cannot execute a Command or detects a prot
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 63 5.6 COMMAND / RESPONSE PAIRS 5.6.1 UTILITY COMMANDS 5.6.1.1 TIME Command Deta
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 64 5.6.1.5 LCD CONTRAST The default is 15. Command Details Set Contrast: <DE
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 65 5.6.1.9 EQUIPMENT TYPE Equipment Type is a command that retrieves the model nu
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 66 5.6.1.11 APPLICATION IDENTIFICATION The Application Identification (AID) comma
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 67 5.6.2.2 ATTENUATOR The default is 10 dB. Command Details Set Attenuator: <
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 68 5.6.2.5 AUTO FAULT RECOVERY The converter output is automatically muted in the
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 69 5.6.2.8 CLEAR PRESET This command is used to clear a preset number. Command D
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 70 Command Details Initialize Command: <DEV/ICT_xx_yy'cr' Confirma
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 71 5.6.3.3 BACKUP MODE This command allows the user to force a backup condition f
iii Table of Contents Customer Support...
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 72 5.6.4.2 MAINTENANCE STATUS Command Details Maintenance Status: <DEV/RMS_&
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 73 5.6.4.5 SUMMARY ALARM STATUS Summary alarm is set to Fault (FT) if any of the
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 74 5.6.4.8 PACKED MAINTENANCE STATUS Packed Maintenance Status: <DEV/PACRMS_&
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 75 5.6.4.10 PACKED ALARM STATUS Packed Alarm Status: <DEV/PACRAS_'cr&ap
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 76 5.6.5.3 LIST ALL ALARMS This command retrieves a list of the stored alarms. T
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 77 5.7 ERROR PROCESSING 5.7.1 GENERAL ERRORS The following Error Responses may be
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 78 5.8 CONVERTER REMOTE COMMAND SUMMARY Table 14. Remote Command Summary Utility
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 79 Status Commands Paragraph Retrieve Configuration Status <DEV/RCS_'
UT4500 Series Up Converter MN/UT4500.IOM Remote Control Revision 2 80 NOTES:
81 Chapter 6. Theory of Operation 6.1 APPLICATIONS This appendix contains a general description of the theory of operation for the Model UT-4500 S