UT4500 Series Up Converter MN/UT4500.IOM
Introduction Revision 2
5
Characteristic Specification
Group Delay
Linear Group Delay
Parabolic Delay
Group Delay Ripple
0.03 ns/MHz
0.01 ns/MHz
2
1 ns Peak-to-Peak
Phase Noise
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Limit (dBc/Hz)
-80
-89
-95
-105
-120
Typical (dBc/Hz)
-83
-92
-97
-109
-124
Remote Control (Rear Panel)
Comm Port EIA-485 or EIA-232
Indicators (Front Panel)
Power On
Mute
Remote
Reference
Stored Fault
Fault
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
Test Points (Front Panel)
RF Sample
IF Sample
Optional L.O. Sample
SMA, -20 dBc Nominal
BNC, -20 dBc Nominal
Power
Voltage
Frequency
Dissipation
90 to 250 Vac Autoranging, optional –48 Vdc
47 to 63 Hz
60 Watts
Environmental
Temperature
Altitude
Humidity
0 to 50° C (32 to 122° F)
10,000 Feet MSL
0 to 95 % Relative
Physical
Width
Height
Depth
Weight
19 Inches (48.30 cm)
1.75 Inches (4.45 cm)
22 Inches (55.90 cm)
15 Pounds (7.00 kg)
MTBF
49,740 hrs. (calculated)
>100,000 hrs. (field experience)
Summary Alarm
Relay Closure
Form C
Zobrazit stránku 22