Zobrazit stránku 212
CDM-600 Satellite Modem Revision 7
Remote Control MN/CDM600.IOM
16–25
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Circuit ID
String
CID= 40 bytes Command or Query
Sets or queries the user-defined Circuit ID string, which
is a fixed length of 40 characters.
Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z
CID=
CID?
CID*
CID#
CID? CID=x
(see description of
arguments)
Outdoor Unit
Comms
enable
ODU= 1 byte, 0 or 1 Command or Query.
Enables or disables communications, via the FSK link,
with a Comtech EF Data transceiver (ODU), where:
0=Disabled
1=Enabled
Example: ODU=0 (selects Disabled)
ODU=
ODU?
ODU*
ODU#
ODU? ODU=x
(see description of
arguments)