2
AUPC
Parameters
APP=
6 bytes Command or Query.
Defines AUPC operating parameters. Has the form abc.cd,
where:
a=Defines action on max. power condition.
(0=do nothing, 1=generate Tx alarm)
b=Defines action on remote demod unlock.
(0=go to nominal power, 1=go to max power)
c.c=target Eb/No value, for remote demod, from 0.0 to
14.9 dB, where numbers above 9.9 use hex
representation for the 1 st character, ie 14.9 is
coded as E.9.
d =Max increase in Tx Power permitted, from
0.0 to 9.0 dB
Example: APP=015.67 (Sets no alarm, max power, 5.6 dB
target Eb/No and 7 dB max power increase.
APP=
APP?
APP*
APP#
APP? APP=abc.cd
(see description of
arguments)