CDD-562L/564 Demodulator with IP Module Revision 2
Appendix D MN/CDD564L.IOM
D–24
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Save System
Configuration
Parameters
SCS= 1 byte value
1 – Save config
Command only
Set to ‘1’ to save all the active system configuration on to the Flash.
SCS=
SCS!
N/
A
SCS=x
(see Description of Arguments)
Software Revision N/
A
34-37 bytes Query only.
Returns the value of the internal software revision installed in the unit.
Example: >0001/SWR=Boot:1.1.1 Bulk1:1.5.1u Bulk2:1.5.1P
SWR!
SWR?
SWR=Boot:x.y.zz Bulk1:x.y.zz
Bulk2:x.y.zz
(see Description of Arguments)
Upgrade Slot USI= 1 bytes, value of
0,1, or 2
Command or Query.
Slot to upgrade new IP firmware where:
0 = Oldest
1 = Image 1
2 = Image 2
Example: UPS=0
USI =
USI!
USI?
USI=x
(see Description of Arguments)
Unit Up Time N/
A
String value Query only
Displays the unit up time in days, hours, minutes & seconds.
Example: >0001/UUT=0 days 0 hours 13 mins 15 secs
N/
A
UUT?
UUT=sssssss
(see Description of Arguments)