Comtech EF Data DMD-2050E Specifikace Strana 1

Procházejte online nebo si stáhněte Specifikace pro Sítě Comtech EF Data DMD-2050E. Comtech EF Data DMD-2050E Product specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 342
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - DMD-2050E

MN-DMD2050E Revision 2 Comtech EF Data is an AS9100 Rev B / ISO9001:2000 Registered Company DMD-2050E Universal Satellite Modem Installa

Strany 2

BLANK PAGE

Strany 3

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–58 Table 3-4. Reed-Solomon Codes Type of Service Data Rate (Kbps)

Strany 4

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–59 rate through the modem. The overhead channel is recovered at t

Strany 5

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–60 Kbps Standard IBS Baud Rate Example Kbps Enhanced Mode Baud R

Strany 6

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–61 The ratio of the Through Terrestrial Data Channel Rate to the

Strany 7

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–62 The user can connect whichever systems on the earth stations th

Strany 8

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–63 The number of user data slots and control words per frame is se

Strany 9

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–64 3.19.2 Aggregate Data Rate The aggregate data rate equals the

Strany 10 - BLANK PAGE

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–65 3.19.3 Overhead Rate Comparison The SCC Overhead Ratio varies

Strany 11 - Table of Contents

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–66 3.19.4 Actual Overhead Rate Calculation The following is the a

Strany 12

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–67 3.20 SCC OVERHEAD CHANNEL SETUP 1. Set the Framing Mode (loca

Strany 13

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iii Table of Contents PREFACE ...

Strany 14

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–68 9. The physical connection to the DMD2050E for the overhead ch

Strany 15 - vii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–69 3.21 Locating the DMD2050E ID Code Operational Procedure Uniqu

Strany 16 - viii

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–70 BLANK PAGE

Strany 17

MN-DMD2050E Revision 2 4–1 Chapter 4. User Interfaces 4.1 User Interfaces The DMD2050E has three interfaces available for typical operations: •

Strany 18

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–2 Table 4-1. Front Panel Functions Area Function VFD Shows operating

Strany 19

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–3 Parameter Type 0 – 9     Clear &  Clear &  IP Address

Strany 20 - xii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–4 4.3 Parameter Setup 4.3.1 Select a Parameter Use the arrow keys to

Strany 21 - xiii

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–5 4.4.1 MODULATOR Main Menu and Parameters 4.4.1.1 NETWORK SPEC (men

Strany 22 - xiv

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–6 4.4.1.2 STRAP CODE The STRAP CODE is another means for quickly sett

Strany 23 - Figures

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–7 DATA MENU Trellis (8PSK) {2/3} TPC (BPSK) {5/16, 21/44} ≤ 20Mbp

Strany 24 - xvi

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E iv CHAPTER 2. INSTALLATION ...

Strany 25 - PREFACE

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–8 DATA MENU TERR FRAMING {NONE, 188, 204} DVB Only DATA POLARITY {I

Strany 26 - Grounding

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–9 4.4.1.5 REED-SOLOMON (menu) IMPORTANT When Reed-Solomon is select

Strany 27 - Low Voltage Directive (LVD)

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–10 4.4.1.7 LOCAL AUPC (menu) NOTE When modems are configured for Rad

Strany 28 - CE Mark

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–11 LOCAL AUPC MENU MINIMUM TX POWER {0 to -45 dB} Set the minimum Tran

Strany 29 - Preface MN-DMD2050E

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–12 LOCAL AUPC MENU TARGET Eb/No {4.0 to 16 dB} Set the desired Eb/No f

Strany 30

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–13 4.4.1.8 REMOTE AUPC (menu) NOTE Remote AUPC Menus are available o

Strany 31 - Chapter 1. Introduction

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–14 8PSK 2/3 {NOT SELECTED, SELECTED} Used to select the mod/code rate

Strany 32 - 1.2.1 Features

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–15 Closed Net All possible combinations are allowed. NOTE: DVB settin

Strany 33 - 1.2.3 Bandwidth Compression

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–16 IF MENU INPUT THRESHOLD (dBm) {-30 to –90} Sets the minimum carrie

Strany 34 - 1.2.7 Physical Description

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–17 DATA MENU SCRAMBLER SEL {NONE, V.35-IESS, V.35 CITT, V.35 EF, IBS w

Strany 35

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E v 3.5.3.3 SCT: Serial Clock Transmit ...

Strany 36

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–18 4.4.2.6 CNC (menu) IMPORTANT When the Carrier-in-Carrier® option

Strany 37 - Chapter 2. Installation

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–19 4.4.3 INTERFACE Main Menu and Parameters 4.4.3.1 TX SETUP (menu)

Strany 38 - 2.2 Installation Safety

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–20 IMPORTANT When Ethernet Interface is selected or EBEM Network spe

Strany 39 - 2.3.4 Electrical Power

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–21 4.4.3.1.1 DROP & INSERT (menu) DROP & INSERT MENU DROP MOD

Strany 40 - 2.3.5 Cables

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–22 4.4.3.2 RX SETUP (menu) RX SETUP MENU CIRCUIT ID Enter the Rx Ci

Strany 41 - 2.5.1 Initial Start Up

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–23 4.4.3.2.1 DROP & INSERT (menu) INSERT MODE {NONE, T1-D4, T1-ES

Strany 42

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–24 4.4.3.3 GENERAL (menu) GENERAL MENU EXT FREQ (MHz) {Variable Throu

Strany 43 - 3.1 DMD2050E Hardware

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–25 MONITOR MENU CORRECTED BER The CBER display shows an estimated corr

Strany 44

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–26 NOTE Port status indicators are: Down: The link is down. Unreso

Strany 45

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–27 4.4.4.2 VOLTAGES (menu) VOLTAGES MENU TEMPERATURE Displays interna

Strany 46

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vi 3.11.12.4 Estimating PSD Ratio from Satmaster ...

Strany 47 - 3.2.2 Baseband Processing

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–28 4.4.5 ALARMS Main Menu and Parameters Alarm details are described

Strany 48

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–29 4.4.6.3 TERMINAL (menu) TYPE {VT-100, WYSE50, VIEWPOINT} Select t

Strany 49

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–30 TCP/IP MENU BOOTp SERVER {128 – 257, default is 206} Only used if

Strany 50 - 3.2.6 Terminal Port

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Strany 51 - 3.2.9 Modem Monitor Status

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–32 4.4.6.7 FTP (menu) PORT {XXXX} Select the desired port number.

Strany 52 - 3.3 Internal Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–33 4.4.6.9 TRANSEC (menu) TRANSEC MENU IP ADDR MASK {XXX.XXX.XXX.XXX}

Strany 53

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–34 4.4.6.10.1 MAIN BOARD (menu) NOTE Only the applicable VCO adjustm

Strany 54

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–35 CNC BOARD (menu) Indicates the part number for the CNC Board. DEBU

Strany 55 - 3.5.1 Clock Selection

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–36 4.4.7 TEST Main Menu and Parameters TEST MENU TX TEST PATTERN {NON

Strany 56 - 3.5.2 TX Clock Options

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–37 TEST MENU IQ SAMPLING {ENABLE/DISABLE} Enables the I & Q patte

Strany 57

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E vii 4.4 Front Panel Main Menus ...

Strany 58 - 3.5.3.1 RX SAT Clock

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–38 4.5 Terminal Mode Control The Terminal Mode Control lets you use a

Strany 59 - Frequency 1 MHz to 20 MHz

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–39 For numerical input, use the number keys to input the data. Press E

Strany 60 - 3.6.3 HSSI Interface

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–40 BLANK PAGE

Strany 61

MN-DMD2050E Revision 2 5–1 Chapter 5. External Connections Figure 5-1. DMD2050E Universal Satellite Modem Front Panel Figure 5-2. DMD2050E Rear

Strany 62 - 3.9 STANAG Turbo Coding

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–2 5.1 Power Connectors, Ground and Switches The DMD2050E units h

Strany 63 - 3.10.1.1 Key Agreement

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–3 5.2 Front Panel Connections 5.2.1 Key Loader Interface Label

Strany 64

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–4 5.3 Rear Panel Connectors CAUTION Before you connect any cab

Strany 65

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–5 5.3.2 EXT REF (J10) Label Description Connector Type Input Lev

Strany 66 - 3.10.1.2.1 Key Derivation

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–6 5.3.4 ALARM (J15) Label Description Connector Type ALARM J15

Strany 67

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–7 5.3.4.1 IBS Network Alarms Configuration IBS Prompt Alarms IBS

Strany 68

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E viii 4.5 Terminal Mode Control...

Strany 69

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–8 5.3.6 ASYNC (J17) Label Description Connector Type ASYNC J17

Strany 70

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–9 5.3.8 MIL-188-114A (J19) Label Description Connector Type MI

Strany 71 - DMD2050E CnC Module

DMD2050E Universal Satellite Modem External Connections MN-DMD2050E Revision 2 5–10 5.3.9 Monitor and Control Connectors J20, J21 Label Descript

Strany 72

MN-DMD2050E Revision 2 6–1 Chapter 6. Maintenance and Troubleshooting 6.1 Periodic Maintenance 6.1.1 Battery Replacement WARNING: DANGER OF EX

Strany 73

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–2 6.2 Troubleshooting 6.2.1 Basic Troubleshooting Pro

Strany 74

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–3 6.3 Alarms 6.3.1 Major Transmit Alarms Alarm Desc

Strany 75

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–4 Alarm Description Status INPUT LVL THRESH Indicates t

Strany 76

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–5 Alarm Description Status TPC CONFLICT CHK Indicates t

Strany 77 - 3.11.6 Margin Requirements

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–6 Alarm Description Status RX AGC LEVEL Indicates Rx le

Strany 78

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–7 Alarm Description Status +3.3V SUPPLY Shows the measu

Strany 79

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E ix 6.4 Alarm Masks ...

Strany 80

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–8 6.4 Alarm Masks The DMD2050E self-monitors and isola

Strany 81

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–9 Alarms are grouped into transmit and receive alarms.

Strany 82

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–10 RX MAJOR (menu) {Pass/Fail} RX MINOR (menu) {Pass/Fa

Strany 83

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–11 NOTE These alarms show the status of the alarms RE

Strany 84

DMD2050E Univeral Satellite Modem Maintenance and Troubleshooting MN-DMD2050E Revision 2 6–12 6.5 IBS Alarms and Actions Figure 6-1 and Table 6-1

Strany 85

MN-DMD2050E Revision 2 7–1 Chapter 7. Technical Specifications 7.1 Modulator Modulator Specifications Modulation BPSK, QPSK, OQPSK, 8-PSK, 8-QA

Strany 86

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–2 Modulator Specifications Turbo (16-QAM) {3/4, 7/8} ≤ 20Mb

Strany 87

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–3 Demodulator Specifications Turbo (OQPSK/QPSK) {1/2, 3/4, 7

Strany 88

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–4 7.5 Terrestrial Interfaces MIL-188-114A, HSSI GiGE 10/100/

Strany 89

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–5 7.11 Data Rate Limits 7.11.1 Non-DVB Non-DVB Data Rate Li

Strany 90

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E x 7.12.14 B/O/QPSK BER Performance (LDPC) ...

Strany 91 - 3.11.15 Glossary

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–6 Non-DVB Data Rate Limits Modulation Code Rate Min Data Rate

Strany 92

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–7 7.11.2 DVB DVB Data Rate Limits Modulation Code Rate DVB M

Strany 93

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–8 DVB Data Rate Limits Modulation Code Rate DVB Mode Min Data

Strany 94 - 3.12.1 LDPC versus TPC

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–9 7.12 BER Specifications 7.12.1 BER Performance (Viterbi)

Strany 95

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–10 7.12.2 BER Performance (Sequential) Figure 7-2. DMD2050E

Strany 96

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–11 7.12.3 BER Performance (Viterbi with Reed-Solomon) Figur

Strany 97

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–12 7.12.4 BER Performance (Turbo) Figure 7-4. DMD2050E B/O

Strany 98 - 3.13 Reed-Solomon Codec

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–13 7.12.5 BER Performance (8PSK Trellis) Figure 7-5. DMD20

Strany 99 - 3.13.3 Interleaving

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–14 7.12.6 BER Performance (8PSK Turbo) Figure 7-6. DMD2050E

Strany 100 - Communications)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–15 7.12.7 BER Performance (16QAM Viterbi) Figure 7-7. DMD20

Strany 101

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xi D.2.2 IP Address ...

Strany 102 - 3.16 Standard IBS Mode

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–16 7.12.8 BER Performance (16QAM Viterbi with Reed-Solomon)

Strany 103 - 3.18 ESC Backward Alarms

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–17 7.12.9 BER Performance (16QAM Turbo) Figure 7-9. DMD2050

Strany 104 - See also:

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–18 7.12.10 BER Performance (OQPSK Turbo) Figure 7-10. DMD2

Strany 105

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–19 7.12.11 BER Performance (BPSK Turbo) Figure 7-11. DMD20

Strany 106 - 3.19.2 Aggregate Data Rate

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–20 7.12.12 BER Performance (8PSK Turbo) Figure 7-12. DMD20

Strany 107

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–21 7.12.13 BER Performance (16QAM Turbo) Figure 7-13. DMD2

Strany 108 - (less than In-Band Rate)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–22 7.12.14 B/O/QPSK BER Performance (LDPC) Figure 7-14. DM

Strany 109

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–23 7.12.15 8PSK / 8QAM BER Performance (LDPC) Figure 7-15.

Strany 110 - Port labeled ASYNC (J17)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–24 7.12.16 16QAM BER Performance (LDPC) Figure 7-16. DMD205

Strany 111

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–25 7.12.17 BER Performance B/O/QPSK (MILSTD 188-165B or STAN

Strany 113 - Chapter 4. User Interfaces

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xii E.4.3.3 PCM-31 ...

Strany 114 - 4.2.3 Numeric Keys

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–26 7.12.18 BER Performance 8-PSK (MILSTD 188-165B or STANAG)

Strany 115 - 4.2.4 LED Lights

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–27 7.12.19 BER Performance 16APSK (MILSTD 188-165B or STANAG

Strany 116 - 4.4 Front Panel Main Menus

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–28 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8 Ra

Strany 117 - 4.4.1.1 NETWORK SPEC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–29 Turbo 0.495 Turbo 0.793 Turbo 0.495 Turbo 0.7931E-3

Strany 118 - 4.4.1.4 DATA (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–30 3/4 Rate 7/8 Rate 3/4 Rate 7/8 Rate1E-3 8.9 dB 10.3

Strany 119

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–31 1/2 Rate 3/4 Rate 7/8 Rate 1/2 Rate 3/4 Rate 7/8

Strany 120

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–32 1/2 Rate 2/3 Rate 3/4 Rate 1/2 Rate 2/3 Rate 3/4 R

Strany 121 - 4.4.1.6 AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–33 1/2 Rate 2/3 Rate 3/4 Rate 7/8 Rate19/20 Rate1/2 Rate

Strany 122 - 4.4.1.7 LOCAL AUPC (menu)

DMD2050E Universal Satellite Modem Technical Specifications MN-DMD2050E Revision 2 7–34 7.13 AGC Output Voltage The AGC Output Voltage is a funct

Strany 123

MN-DMD2050E Revision 2 A–1 Appendix A. Product Options A.1 Hardware Options These enhanced interface cards are available: DC Input Prime Power

Strany 124

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiii APPENDIX H. ETHERNET DATA INTERFACE SETUP...

Strany 125 - 4.4.1.9 ITA (menu)

DMD2050E Universal Satellite Modem Product Options MN-DMD2050E Revision 2 A–2 BLANK PAGE

Strany 126 - 4.4.2.1 NETWORK SPEC (menu)

MN-DMD2050E Revision 2 B–1 Appendix B. Front Panel Upgrades and Demonstration Mode B.1 Introduction The DMD2050E Universal Satellite Modem allow

Strany 127 - 4.4.2.3 IF (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–2 B.3.1 Record the Features and Options Find and record

Strany 128 - 4.4.2.4 DATA (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–3 B.3.2 Record the Unit ID Comtech requests the Unit ID

Strany 129 - 4.4.2.5 REED-SOLOMON (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–4 B.3.4 Install the Code Use the front panel to enter t

Strany 130 - Hz) between the

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–5 B.3.5 Demonstration Mode Considerations The unit uses

Strany 131 - 4.4.3.1 TX SETUP (menu)

DMD2050E Universal Satellite Modem Front Panel Upgrade Procedure MN-DMD2050E Revision 2 B–6 B.3.6 Cancel the Demonstration Mode IMPORTANT If you

Strany 132

MN-DMD2050E Revision 2 C–1 Appendix C. Carrier Control C.1 Carrier Control and Alarms If a TX major alarm occurs, modulator output is muted auto

Strany 133

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–2 C.3 Carrier States These are the carrier states: • Carrier OFF •

Strany 134 - 4.4.3.2 RX SETUP (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–3 2. The output starts again automatically. C.3.4 Carrier VSAT The ca

Strany 135

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xiv Tables Table 3-1. Spectral Efficiency using DoubleTalk Carrier-

Strany 136 - 4.4.3.3 GENERAL (menu)

DMD2050E Universal Satellite Modem Carrier Control MN-DMD2050E Revision 2 C–4 BLANK PAGE

Strany 137 - 4.4.4.1 LINK STATUS (menu)

MN-DMD2050E Revision 2 D–1 Appendix D. Web Interface Setup Guide D.1 Introduction The web interface lets Radyne products connect and communicate

Strany 138

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–2 D.2.2 IP Address IMPORTANT Before you set an IP address, c

Strany 139 - 4.4.4.4 ITA (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–3 D.3.2 User Account Data IMPORTANT All entries are case-sen

Strany 140 - 4.4.6.2 REMOTE CONTROL

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–4 IMPORTANT All entries are case-sensitive. To set up a Use

Strany 141 - 4.4.6.5 TCP/IP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–5 D.2 Reset a User Account Sometimes, it is necessary to rese

Strany 142

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–6 D.4 Equipment Website Once you know that the modem is acces

Strany 143 - 4.4.6.6 SNMP (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–7 The Introduction page shows general information, such as: •

Strany 144 - 4.4.6.8 WEB (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–8 D.5 Web Page Appearance This page displays the Monitor and

Strany 145 - 4.4.6.9 TRANSEC (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–9 D.6 Configure Web Browsers for the Radyne WEB Interface D

Strany 146

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xv Figures Figure 1-1. DMD2050E Universal Satellite Modem Front Pa

Strany 147 - 4.4.6.10.2 FEATURES (menu)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–10 D.6.2.1 Change the encoding: Click View on the Firefox men

Strany 148

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–11 D.6.2.2 Install the Internet Explorer Tab V2 add-on The In

Strany 149

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–12 D.6.3 Configure Chrome for the Radyne WEB Browser When you

Strany 150 - 4.5.1 Terminal Mode Screens

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–13 D.6.3.1 Change the encoding On the Chrome address bar, cli

Strany 151

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–14 D.6.3.2 Install the Internet Explorer Tab for Chrome The I

Strany 152

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–15 D.6.4 Configure Safari for the Radyne WEB Browser IMPORTA

Strany 153

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–16 D.6.4.2 Reset the Ethernet M&C port To reset the Ether

Strany 154 - 5.1.2 Power Switch

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–17 On the Monitor & Control, Password Setup or IP Administ

Strany 155 - 5.2.1 Key Loader Interface

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–18 D.6.4.4 Change the encoding Click View on the Safari menu

Strany 156 - 5.3 Rear Panel Connectors

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–19 D.6.5 Configure Maxthon for the Radyne WEB Browser On the

Strany 157 - 5.3.2 EXT REF (J10)

DMD-2050E Universal Satellite Modem Revision 2 Table of Contents MN-DMD2050E xvi Figure D-3. Monitor and Control Web Page ...

Strany 158 - 5.3.4 ALARM (J15)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–20 D.6.5.1 Change the browser mode Two browser modes are poss

Strany 159 - 5.3.5 EXT CLK (J16)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–21 D.6.5.2 Change the encoding On the Monitor & Control p

Strany 160 - 5.3.6 ASYNC (J17)

DMD2050E Universal Satellite Modem Web Browser Setup Guide MN-DMD2050E Revision 2 D–22 BLANK PAGE

Strany 161 - 5.3.8 MIL-188-114A (J19)

MN-DMD2050E Revision 2 E–1 Appendix E. Drop and Insert (Standard and Efficient Options) E.1 Introduction Drop and Insert (D&I) functions

Strany 162

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–2 Objective Menu Path Requirement Find the G.703 interface c

Strany 163 - Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–3 Figure E-1. Looped Modems Figure E-2 Looped Modems wi

Strany 164 - 6.2 Troubleshooting

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–4 E.4 Functional Descriptions E.4.1 Drop Only When Drop is

Strany 165 - 6.3.2 Major Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–5 Figure E-4 Insert Only with Eternal Frame Source Figure

Strany 166 - 6.3.3 Minor Tx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–6 E.4.3 Data Formats The terrestrial data formats compatibl

Strany 167 - 6.3.3.1 Minor Rx Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–7 drop and n timeslots to insert where n = 1, 2, 3, 4, 5, 6,

Strany 168

xix PREFACE About this Manual This manual gives installation and operation information for the Comtech EF Data DMD2050E Universal Product Modem.

Strany 169

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–8 SATCh TS Enter to Edit Any changes made in these displa

Strany 170 - 6.4.1.2 Minor Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–9 Example : For a modem w/ Drop and Insert enabled at a data

Strany 171 - 6.4.3 Latched Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–10 Map Copy RX EDIT > RX ACTIVE 4. Press &l

Strany 172

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–11 E.5.1 Data Rate Data Rate affects the Drop and Insert fu

Strany 173 - 6.4.4 Backward Alarms

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–12 n = 12, data rate = 768000 n = 15, data rate = 960000 n =

Strany 174 - 6.5 IBS Alarms and Actions

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–13 E.5.3.1 Insert Terrestrial Frame Source The Insert Terre

Strany 175 - 7.1 Modulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–14 Under Tx D&I: Set Drop Mode = T1-D4

Strany 176 - 7.2 Demodulator

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–15 Set Conv Enc = 3/4 Rate VIT Under Interface: Unde

Strany 177 - 7.4 Monitor and Control

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–16 Set Rx Type according to your hardware configuration

Strany 178

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–17 E.5.4.1 D&I Clock Setup Examples Figure E-7 Trans

Strany 179 - 7.11.1 Non-DVB

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xx Electrical Safety The DMD2050E has been shown to comply with the EN 60950 Safety

Strany 180

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–18 Figure E-9 Rx Only With Trunk Figure E-10 Rx Only No

Strany 181 - 7.11.2 DVB

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–19 E.6 D&I Maps and Map Editing The Drop and Insert mul

Strany 182

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–20 Therefore, in this case only the first six entries of the

Strany 183 - 7.12 BER Specifications

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–21 map through the modem’s LCD; when editing is complete, th

Strany 184 -

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–22 time slots of the T1 or E1 frame. The Multiplexer would

Strany 185 - Viterbi Decoder Reed

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–23 This would be used with T1 frames where channels 1 throug

Strany 186 - Turbo Decoder

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–24 E.8 Prerequisite In order for a modem to be configured f

Strany 187 - Trellis

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–25 E.9 Efficient Drop and Insert Mode With Efficient Drop a

Strany 188

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–26 600 station in-band rate. In most cases, this

Strany 189 - Viterbi

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–27 E.9.4 Calculating the Efficient D&I Rate with Enhanc

Strany 190 - Reed Solomon

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxi Environmental Do not operate the DMD2050E in an environment where the unit is ex

Strany 191

DMD2050E Universal Satellite Modem Efficient Drop and Insert MN-DMD2050E Revision 2 E–28 X = Truncation of (1.92) X = 1 Add 1 * 5 * 125 bps to

Strany 192

MN-DMD2050E Revision 2 F–1 Appendix F. TCP/IP Ethernet Setup F.1 Introduction The modem supports SNMP, FTP protocols and the Web Browser. Utili

Strany 193

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–2 • MODEM IP ADDR 010.000.000.001 • SERVER IP ADDR 010.0

Strany 194

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–3 and loop back addresses will not be allowed. Example Server I

Strany 195

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–4 F.4 Ethernet Test F.4.1 Connecting the Modem Ethernet Cable

Strany 196 - LDPC Decoder

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–5 1. Click the Start button. 2. Select Settings and click Co

Strany 197

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–6 Internet Protocol (TCP/IP) Properties 9. Select “Use the fo

Strany 198

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–7 F.5 Testing the Ethernet Connection using the Ping Program (O

Strany 199

DMD2050E Universal Satellite Modem TCP/IP Ethernet Setup MN-DMD2050E Revision 2 F–8 4. If the ping is unsuccessful the screen will display: C:\>

Strany 200 - MILSTD 188-165B

MN-DMD2050E Revision 2 G–1 Appendix G. AUPC Operation G.1 Automatic Uplink Power Control (AUPC Operation) The modem has an optional built-in pro

Strany 201 - MILSTD 188

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxii CE Mark Comtech EF Data declares that the DMD2050E meets the necessary requirem

Strany 202

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–2 drop in the remote Eb/No, it slowly begins to raise the output power,

Strany 203

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–3 The local receiver must be tuned and locked to the transmitter and th

Strany 204

DMD2050E Universal Satellite Modem AUPC Operation MN-DMD2050E Revision 2 G–4 When the rain diminishes, Local modem will see the remote Es/No begin

Strany 205

MN-DMD2050E Revision 2 H–1 Appendix H. Ethernet Data Interface Setup H.1 Configuring the modem to use the Ethernet Data Interface (Optional) Whe

Strany 206

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–2 When Ethernet Data Interface is selected, the Tx Clock

Strany 207

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–3 When Port 4 is selected for Daisy Chain, any data rece

Strany 208 - 7.13 AGC Output Voltage

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–4 H.1.5 Setting Up The DMD2050E Ethernet Bridge To Opera

Strany 209 - Appendix A. Product Options

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–5 H.1.6 Packet Statistics The following statistics are a

Strany 210

DMD2050E Universal Satellite Modem Ethernet Data Interface Setup MN-DMD2050E Revision 2 H–6 BLANK PAGE

Strany 211 - B.3 Procedures

MN-DMD2050E Revision 2 I–1 Appendix I. Strap Codes I.1 Strap Codes The Strap Code is a quick set key that sets many of the modem parameters. For

Strany 212

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiii Product support On the web http://www.comtechefdata.com/support.asp Return mat

Strany 213 - B.3.2 Record the Unit ID

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–2 NOTE Dis = Disable in Table I-1. Table I-1. Strap Codes Strap Code (D

Strany 214 - B.3.4 Install the Code

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–3 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Strany 215

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–4 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Strany 216

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–5 Strap Code (Decimal) Data Rate (Kbps) Overhead Code Rate Type Framing Ty

Strany 217 - Appendix C. Carrier Control

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–6 I.2 Sample Applications The following section provides brief applicatio

Strany 218 - C.3.3 Carrier AUTO

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–7 I.2.1 Operational Case Examples IMPORTANT Make sure to set the data r

Strany 219 - C.3.5 CARRIER RTS

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–8 Set desired Tx frequency and power level Turn IF on Demodulator

Strany 220

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–9 I.2.1.2 Case 2: IBS 1.544 Mbps, 3/4 Rate Viterbi Start with the Data R

Strany 221 - Setup Guide

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–10 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Strany 222 - D.3.1 Default User Accounts

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–11 I.2.1.3 Case 3: Closed Network, 3/4 Rate Viterbi, IBS Overhead Start

Strany 223 - D.1 User Account Setup

ER-DMD2050E-EA2 Rev - PLM C-0028800 Errata A for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3, Theory of Operati

Strany 224 - D.1.2 Edit the Access Group

DMD2050E Universal Product Modem Revision 2 Preface MN-DMD2050E xxiv Warranty Policy Comtech EF Data products are warranted against defects in mater

Strany 225 - D.3 Confirmation

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–12 Demodulator: Method 1 - Under Interface Menu: Set Interface type Se

Strany 226 - D.4 Equipment Website

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–13 I.2.1.4 Case 4: Loop Timing Example Method 1 - Under Interface Menu:

Strany 227

DMD2050E Universal Satellite Modem Strap Codes MN-DMD2050E Revision 2 I–14 BLANK PAGE

Strany 228 - D.5 Web Page Appearance

MN-DMD2050E Revision 2 J–1 Appendix J. ITA Operation J.1 Information Throughput Adaptation (ITA Operation) Information Throughput Adaptation (IT

Strany 229

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–2 J.1.1 Properties of ITA on the DMD2050E: • The DMD2050E output power

Strany 230

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–3 J.1.2 Basic Setup (Example) The modems will be initially configured i

Strany 231

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–4 J.1.2.1 Initial DMD2050E Modem Setup Table J-2 - Initial Modem Setup

Strany 232

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–5 Figure J-1 - Initial Setup DMD2050E, Modulator IF

Strany 233 - D.6.3.1 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–6 Figure J-2 - Initial Setup DMD2050E, Modulator Data

Strany 234

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–7 Figure J-3 - Initial Setup DMD2050E, Modulator ITA

Strany 235

MN-DMD2050E Revision 2 1– 1 Chapter 1. Introduction 1.1 Overview The new DMD2050E Satellite Modem (Figure 1-1) breaks new ground in flexibility a

Strany 236

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–8 Figure J-4 - Initial Setup DMD2050E, Demodulator IF

Strany 237

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–9 Figure J-5 - Initial Setup DMD2050E, Demodulator Data

Strany 238 - D.6.4.4 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–10 Figure J-6 - Initial Setup DMD2050E, Demodulator ITA At this point

Strany 239

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–11 Table J-3 - ITA Setup FW: F05280-AH28 REV 4.4.28 (7/06 9:47)MAIN

Strany 240

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–12 The ITA Menu Functions and their descriptions are shown in Table J-4

Strany 241 - D.6.5.2 Change the encoding

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–13 Table J-5. Receive ITA Functions Function AUPC Available Options Desc

Strany 242

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–14 Table J-6 – ITA Waveform Masks (Modulator UUT) DMD2050E MENU SETTINGS

Strany 243 - E.2 System Requirements

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–15 Table J-7 – ITA Waveform Masks (Demodulator UUT) DMD2050E MENU SETTIN

Strany 244 - E.3 Configuration Examples

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–16 Table J-8 – ITA Waveform Masks (Reference Modulator) DMD2050E MENU SE

Strany 245 - Figure E-1. Looped Modems

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–17 Table J-9 – ITA Waveform Masks (Reference Demodulator) DMD2050E MENU

Strany 246 - E.4.2 Insert Only

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 2 The DMD2050E supports a full range of Industry Standard Interfaces that i

Strany 247

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–18 Figure J-7 - Initial Setup DMD2050E, Modulator ITA

Strany 248 - E.4.3.3 PCM-31

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–19 Figure J-8 - Initial Setup DMD2050E, Demodulator ITA To setup ITA Mo

Strany 249 - E.4.3.6 T1-ESF/T1-ESF-S

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–20 Figure J-9- Initial Setup DMD2050E, Modulator ITA (Enabled)

Strany 250

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–21 Figure J-10 - Initial Setup DMD2050E, Demodulator ITA (Enabled)

Strany 251

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–22 Figure J-11 –DMD2050E I/Q for BPSK 2/3

Strany 252

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–23 Figure J-12 –DMD2050E ITA Status for QPSK 2/3

Strany 253 - E.5.1 Data Rate

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–24 Figure J-13 –DMD2050E I/Q for QPSK 2/3

Strany 254

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–25 Figure J-14 –DMD2050E ITA Status for 16APSK 1/2

Strany 255 - Example 1:

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–26 Figure J-15 –DMD2050E I/Q for 16APSK 1/2

Strany 256

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–27 Figure J-16 –DMD2050E ITA Status for 8PSK 3/4

Strany 257 - Example 2:

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 3 • Switchable between spur-free 70/140 MHz and L-Band operations • AC or

Strany 258

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–28 Figure J-17 –DMD2050E I/Q for 8PSK 3/4

Strany 259

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–29 Figure J-18 –DMD2050E ITA Status for 16APSK 7/8

Strany 260

DMD2050E Universal Satellite Modem ITA Operation MN-DMD2050E Revision 2 J–30 Figure J-19 –DMD2050E I/Q for 16APSK 7/8 At this point changing the

Strany 261

Copyright © Comtech EF Data, 2011. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Strany 262

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 2 GNU GENERAL PUBLIC LICENSE Version 2, June 1991 Copyright (C) 1989, 1991

Strany 263

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 3 either of that version or of any later version published by the Free Software Founda

Strany 264

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 4 writing it). Whether that is true depends on what the Library does and what the pro

Strany 265

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 5 It is not the purpose of this section to induce you to infringe any patents or other

Strany 266 - E.8 Prerequisite

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 6 * This can be in the form of a textual message at program startup or * in document

Strany 267

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 7 Darren Tucker Sun Microsystems The SCO Group * Redistribution and use in sou

Strany 268

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 4 1.2.4 Interfaces Industry-standard interfaces include: • MIL-188-114 (

Strany 269

Licensed Software Revision 0 TRANSEC Module AD-TRANSEC-LICNS 8 This page is intentionally blank.

Strany 271 - F.1 Introduction

2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX

Strany 272

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 5 1.2.7.1 Dimensional Envelope

Strany 273

DMD2050E Universal Product Modem Introduction MN-DMD2050E Revision 2 1– 6 1.3 Configurations and Options The DMD2050E has several configuration p

Strany 274 - Network)

MN-DMD2050E Revision 2 2–1 Chapter 2. Installation 2.1 Unpacking and Inspection CAUTION Do not damage the carton contents with a cutting tool.

Strany 275

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–2 2.2 Installation Safety The unit is shipped fully assembled. Do not r

Strany 276

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–3 2.3.1 Location The unit is intended for indoor use only. Do not instal

Strany 277

ER-DMD2050E-EA2 Rev - PLM C-0028800 Blank Page

Strany 278

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–4 2.3.5 Cables To meet EMC directives, make sure to use shielded cables

Strany 279 - Appendix G. AUPC Operation

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–5 IMPORTANT Strap Code 26 can set the following modem configuration. T

Strany 280 - G.1.3 Near Side AUPC

DMD2050E Universal Satellite Modem Installation MN-DMD2050E Revision 2 2–6 BLANK PAGE

Strany 281 - G.1.4 EBEM AUPC

MN-DMD2050E Revision 2 3–1 Chapter 3. Theory of Operation 3.1 DMD2050E Hardware The DMD2050E is based on a two printed circuit card (minimum con

Strany 282

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–2 3.1.1 DMD2050E L-Band/IF Printed Circuit Card The L-Band/IF Pri

Strany 283 - Interface Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–3 3.1.2 DMD2050E Baseband Processing Printed Circuit Card The adv

Strany 284 - H.1.2 Ethernet Daisy Chain

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–4 Figure 3-3. DMD2050E Baseband Processing Card Block Diagram The

Strany 285 - H.1.4 Ethernet QOS Queue

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–5 The M&C System is based on a powerful microprocessor with a

Strany 286

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–6 Figure 3-4. DMD2050E Universal Satellite Modem Functional Block

Strany 287 - H.1.6 Packet Statistics

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–7 The Reed-Solomon Encoder, encodes the data into Reed-Solomon Blo

Strany 288

ER-DMD2050E-EB2 Rev - PLM C-0028804 Errata B for MN-DMD2050E Rev 2 Comtech EF Data Documentation Update Subject: Chapter 3 and Chapter 4 refe

Strany 289 - Appendix I. Strap Codes

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8 • Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Strany 290

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–9 3.2.8 Ethernet M&C Port This port is dedicated for Ethernet

Strany 291

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–10 3.3 Internal Clock The time and date is kept in order to ‘tim

Strany 292

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–11 Figure 3-5. Loopback Functional Block Diagram

Strany 293

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–12 Figure 3-6. Loopback Functional Block Diagram

Strany 294 - I.2 Sample Applications

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–13 Figure 3-7. Loopback Functional Block Diagram 3.5 DMD2050E Cl

Strany 295

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–14 SDTTTx CLKSRCHigh Stability OscillatorSTCLOCK & DATAEXT REF

Strany 296

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–15 3.5.2.1 SCTE: Serial Clock Transmit External The SCTE clock is

Strany 297

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–16 3.5.3 RX Buffer Clock Options The modem supports a number of

Strany 298

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–17 3.5.3.3 SCT: Serial Clock Transmit If SCT clock is selected

Strany 299

DMD2050E Universal Satellite Modem User Interfaces MN-DMD2050E Revision 2 4–31 4.4.6.6 SNMP (menu) A description of OID organization is provided

Strany 300

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–18 3.6 Transmit Timing Options As shown in Figure 3-7, Transmit T

Strany 301

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–19 3.6.4 Ethernet Data Interface (Optional) The modem support a s

Strany 302

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–20 3.8 Ebem Framing Unit The DMD2050E EBEM framing Unit provides

Strany 303 - Appendix J. ITA Operation

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–21 3.10 FIPs TRANSEC Module The DMD2050E FIPS Security Module pro

Strany 304

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–22 IdleWaiting for Embedded ChannelTX OFFEvent: TX ONAction: NoneW

Strany 305 - J.1.2 Basic Setup (Example)

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–23 IdleWaiting for Key RolloverStartupEvent: Key Agreement Messag

Strany 306

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–24 3.10.1.2 Key Agreement Algorithm The key agreement algorithm

Strany 307

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–25 After you have enabled Encryption from the front panel, set up

Strany 308

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–26 Figure 3-12. DMD2050E Handheld Key Loader 3.11 DoubleTalk Car

Strany 309

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–27 3.11.1 What is DoubleTalk Carrier-in-Carrier? The DMD2050E Do

Strany 310

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–8  Modem Status, Alarms & Contact Closures (Section 3.2.9) 3

Strany 311

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–28 • The transponder needs to be “bent-pipe” – meaning no on-boar

Strany 312

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–29 Figure 3-13. Conceptual Block Diagram In a number of ways, CnC

Strany 313 - Table J-3 - ITA Setup

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–30 • The ratio of power spectral density is normally less than 11

Strany 314

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–31 Figure 3-11 shows the same link using the DMD2050E equipped wi

Strany 315

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–32 Traditional Full Duplex Link Duplex Link with Doub

Strany 316

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–33 QPSK 3/4 1.50 3.00 QPSK 7/8 1.75 3.50 8-QAM 2/3 2.00 4.00

Strany 317

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–34 Figure 3-17. DoubleTalk Carrier-in-Carrier Signals Referring t

Strany 318

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–35 Unwanted interfering signal suppression of 30 dB or more has be

Strany 319

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–36 involves trying different FEC and modulation combinations with

Strany 320

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–37 Carrier-in-Carrier link design involved trying different Modul

Strany 321

ER-DMD2050E-EB2 Rev - PLM C-0028804 Blank Page

Strany 322

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–38 Link parameters and LST summary for QPSK, LDPC 2/3 with Carrier

Strany 323

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–39 The link budget summary for the different MODCOD combinations i

Strany 324

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–40 While the traditional link was based on QPSK, TPC 3/4 and requi

Strany 325

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–41 3.11.9.3 Power Limited Links Carrier-in-Carrier can provide su

Strany 326

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–42 Whereas the original link used 8-PSK TPC 3/4, the Carrier-in-Ca

Strany 327

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–43 Step Procedure 1c Make sure CnC function is OFF at both sites.

Strany 328

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–44 3.11.11 Validating Carrier-in-Carrier Performance Carrier-in-C

Strany 329

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–45 3.11.12 Operational References 3.11.12.1 Carrier-in-Carrier L

Strany 330

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–46 3.11.12.2 Estimating PSD Ratio PSD can be estimated from a lin

Strany 331

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–47 3.11.12.4 Estimating PSD Ratio from Satmaster 3.11.12.5 Esti

Strany 332

Copyright © Comtech EF Data, 2013. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.

Strany 333 - TRANSEC Module

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–48 3.11.13 DoubleTalk Carrier-in-Carrier Specifications Operatin

Strany 334

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–49 3.11.14 Carrier-in-Carrier Summary Comtech EF Data’s DoubleTal

Strany 335

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–50 Leased bandwidth Almost all satellite operators charge for the

Strany 336

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–51 C/N = C/No – 10 log B [where B is bandwidth in Hz] Eb/No = C/No

Strany 337

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–52 exhibits inherently low decoding latency compared with TCC, and

Strany 338

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–53 It can be seen from this graph that, for Code Rates above 3/4,

Strany 339

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–54 Mode Code Rate/Modulation Lower Data Rate Limit (kbps) Upper Da

Strany 340

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–55 Table 3-3. Comparison of all Comtech EF Data TPC and LDPC Modes

Strany 341

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–56 3.12.2 TPC and LDPC Summary FOR AGAINST Exceptionally good BE

Strany 342 - • 333 • 2161 FAX

DMD2050E Universal Satellite Modem Theory of Operation MN-DMD2050E Revision 2 3–57 When the signal is received and demodulated by the Receiving Mo

Komentáře k této Příručce

Žádné komentáře