CRS-170A L-Band 1:1 Redundancy Switch MN/CRS170A.IOM
Cables and Connections Revision 13
5–29
5.5.1.2 Unit-to-Switch IF Interface Connection
Excluding the CDM-840s, the KT-0000160 CRS-170A L-Band 1:1 Redundancy Kit
(Sect. 5.2.1) provides all components shown in Figure 5-24.
EXAMPLE: The Tx IF from ‘Unit A’ connects to the Tx IF port ‘J5 | Tx A’ on the
CRS-170A; similarly, the Tx IF from ‘Unit B’ connects to the Tx IF port ‘J6 | Tx B’ on
the CRS-170A.
The same logic applies for the Rx IF connections. It is important to note that failure
to observe this requirement will result in system malfunction.
CEFD Part No. Qty Description
CA/RF10453-4 4 RoHS-Compliant Cable IF (Tx/Rx), 50Ω Type ‘N’, 4’
Figure 5-24. CDM-840 Unit-to-Switch L-Band IF Connections