Comtech EF Data CDM-710L Specifikace Strana 173

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 252
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 172
CDM-710 Broadcast Satellite Modem Revision 10
Remote Control MN/CDM710.IOM
A–11
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response
to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
Tx Power Level TPL= 5 bytes Command or Query.
Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +05.0 and –20.0 dBm.
L-Band: -25.0 to –05.0 dBm
70/140 MHz: -20.0 to +00.0 dBm
Note: Beyond –20 dBm is beyond the specification.
Example: TPL = -13.4
TPL=
TPL?
TPL*
TPL#
TPL?
TPL=sxx.x
Tx Carrier State TXO= 1 byte Command or Query.
Tx Carrier State, where:
0=OFF due to front panel or remote control command
1=ON
Example: TXO=1 (Tx Carrier ON)
TXO=
TXO?
TXO*
TXO#
TXO? TXO=x
Tx Output
Impendance
IMP= 1 byte Command or Query.
Tx output impedance, where:
0=50 Ohm
1=75 Ohm
Example: IMP=0 (Set impedance to 50 Ohms)
* NOTE: Setting Tx Impedence is only possible on 70/140 Mhz
units.
IMP=
IMP?
IMP*
IMP#
IMP? IMP=x
Tx Data Rate N/A 10 bytes Query Only.
Composite Tx Data rate, in kbps.
Resolution=1 bps.
Example: TDR=002047.999 (which is 2047.999 kbps)
TDR?
TDR*
TDR#
TDR? TDR=xxxxxx.xxx
Zobrazit stránku 172
1 2 ... 168 169 170 171 172 173 174 175 176 177 178 ... 251 252

Komentáře k této Příručce

Žádné komentáře