Zobrazit stránku 53
System and Design Manual, Revision 2
3–12 Theory of Operation
The sequence is illustrated in Figure 3-2.
CALLING NODE NMS C
A
LLED NODE
CIRCUIT ASSIGNMENT CIRCUIT ASSIGNMENT
STATUS (OK)
CONFIGURE TRAFFIC
MODEM AND TURN
M
AND RECEIVE ON
ODEM TRANSMIT
CONFIGURE TRAFFIC
MODEM AND TURN
M
AND RECEIVE ON
ODEM TRANSMIT
TRAFFIC MODEM
LOCKS
CIRCUIT REQUEST
REQUEST FOR A
DATA CIRCUIT VIA
THE USER PORT
TRAFFIC MODEM
LOCKS
STATUS (OK)
Figure 3-2. User-Initiated Circuit Setup
The video circuit setup is similar to that of the data circuit.
Circuit Termination
A data or video circuit termination could be initiated by:
The MIDAS Controller, in response to operator action
The traffic node, due to the following:
User port command
RTS/DTR goes inactive
Traffic modem loses lock
4
Call duration expires (for a scheduled circuit)
(For CiM Modems only) - Absence of IP packets destined for a
satellite route through the duration of the user configurable timeout
period.
4
The time from the modem losing lock to circuit termination is configurable.