  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - MiniMACMiniMAC

MiniMACMiniMACMiniMACMiniMACOperation ManualOperation ManualOperation ManualOperation ManualPart Number MN/MiniMAC.OMRevision 0

Strany 2

Rev. 0 7–17Chapter 7 SMS-7000 Protection SwitchScreensThis chapter describes the SMS-7000 Protection Switch screens, which are used tocontrol all func

Strany 3

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–177.5.3.2.1 Back up Modulator ConfigurationOn the BACKUP MODULATOR CONFIGUR

Strany 4 - OVERVIEW SCREEN

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–18 Rev. 0To check the status of one or more backup modulators:1. Choose each MOD BX

Strany 5 - SYSTEM MENUS

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–197.5.3.3 Prime Demodulator ConfigurationOn the PRIME DEMODULATOR CONFIGURAT

Strany 6 - ALARMS MENUS

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–20 Rev. 0To check the status of one or more demodulators:1. Choose each DMD X field

Strany 7 - USER MENUS

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–217.5.3.4 Backup Demodulator ConfigurationTo change the active status of a b

Strany 8 - OPTIONS MENU

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–22 Rev. 07.5.3.5 Modem PriorityThe MODEM PRIORITY screen will display the modem sta

Strany 9 - SDM-300 MODEM

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–237.5.3.6 Modem Online DelayOn the MODEM ONLINE DELAY screen, the user can c

Strany 10 - SMS-7000 Protection Switch

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–24 Rev. 07.5.3.7 D&I G.703 DataIf the modems in the switch system are configur

Strany 11 - V2200 DUAL CONVERTER

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–257.5.3.8 External ClockOn the EXTERNAL CLOCK screen, the user can select BA

Strany 12 - OTHER DEVICES

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–26 Rev. 07.5.3.9 Insert Data InputOn the INSERT DATA INPUT screen the user can sel

Strany 13 - TASK MANAGER

Rev. 0 8–18Chapter 8 V2200 DUAL CONVERTERSCREENSThis chapter describes the V2200 Dual Converter Control screen. The following subjectswith the section

Strany 14 - SPREADSHEET

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–277.5.4 System Configuration7.5.4.1 Verify Active Modem ConfigurationThe VE

Strany 15 - CONFIGURING ALARMS

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–28 Rev. 07.5.4.2 Load All Active ModemsTo load all active modem configurations:1.

Strany 16 - TROUBLESHOOTING

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–297.5.4.3 Load Prime/Backup ModemClick on the LOAD PRIME MODEM OR LOAD BU-M

Strany 17 - Glossary

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–30 Rev. 07.5.4.4 Load Prime Modem AddressClick on the LOAD PRIME MODEM ADDRESS but

Strany 18

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–317.5.4.5 Prime Modem AssignmentClick on the PRIME MODE ASSIGNMENT button, a

Strany 19

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–32 Rev. 07.5.4.6 Modem Control Baud RateClick on the MODEM CONTROL BAUD RATE butto

Strany 20

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–337.6 Set Menus7.6.1 Set Mode RemoteThe switch must be in the Remote Mode t

Strany 21 - C.1 Troubleshooting

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–34 Rev. 07.6.2 Acknowledge Command Accepted ResponseThe MiniMAC will respond with

Strany 22 - 2 and 5 seconds

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–357.6.3 Mode – M:NThe switch can be configured to have 1 or 2 backups in th

Strany 23 - C.2 Debugging the Services

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–36 Rev. 07.6.4 Mode – Switch DEP/INDEach backup can be configured to operate in th

Strany 24 - C.2.1 Saving Debug to a File

Rev. 0 9–19Chapter 9. OTHER DEVICESThis chapter describes other EFData devices. The following subjects with the sectionnumbers are described in this c

Strany 25 - C–6 Rev. 0

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–377.7 Command AuthorityThe Command Authority window gives the system user th

Strany 26 - C.3 Using the COMM Window

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–38 Rev. 0This page is intentionally left blank.

Strany 27 - C–8 Rev. 0

SDM-300 Modem Screens MiniMAC Rack Management System6–2 Rev. 0D&I CommandsSystem/MUX PCBSystem CommandsMUX PCBControl Mode & Authority MenusSe

Strany 28 - B.1 Introduction

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–36.1 Modem Control ScreensThe MODEM CONTROL screen is displayed by selecting a modem fro

Strany 29 - B.2 Configuring Alarms

SDM-300 Modem Screens MiniMAC Rack Management System6–4 Rev. 06.2 Modem Tabs6.2.1 Modulator/DemodulatorAll modulator/demodulator configuration status

Strany 30 - Sound/Setup Sound

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–56.2.2 Interface TabThe INTERFACE Tab displays the interface configuration parameters. Th

Strany 31 - Alarm and click on Open

SDM-300 Modem Screens MiniMAC Rack Management System6–6 Rev. 06.2.3 AUPC/D&I TabThe AUPC/D&I Tab displays the status information for AUPC (Aut

Strany 32 - B–6 Rev. 0

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–76.3 View MenusThe VIEW menu allows the user to change the view to OVERVIEW or FAULTS.6.3

Strany 33

SDM-300 Modem Screens MiniMAC Rack Management System6–8 Rev. 06.3.2 View – Fault ScreensThe FAULT Screen exhibits faults that can be acknowledged, st

Strany 34 - B–8 Rev. 0

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–9To Acknowledge a new flashing fault, proceed as follows:Command ResponseClick on Faulted

Strany 35

Rev. 0 10–110Chapter 10 ENDING THE PROGRAM WithTASK MANAGERThis chapter describes ending the program using the Task Manager. The followingsubjects wit

Strany 36 - B–10 Rev. 0

SDM-300 Modem Screens MiniMAC Rack Management System6–10 Rev. 06.3.3 View - Stored FaultsUp to 10 faults can be stored for each stored fault category

Strany 37

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–11The Command Accepted Message window will appear with the response value of therequested

Strany 38

SDM-300 Modem Screens MiniMAC Rack Management System6–12 Rev. 06.4 Configure MenuThe CONFIGURE menu allows the user to:• Edit Labels• Setup Alarms• Eb

Strany 39

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–136.4.1.1 Unlocking and Editing LabelsWhen the user clicks on LOCK LABELS, the Command C

Strany 40 - 10.1 Using the Task Manager

SDM-300 Modem Screens MiniMAC Rack Management System6–14 Rev. 06.4.1.2 Editing Labels Data Entry WindowOnce the LOCK LABELS have been unlocked, Click

Strany 41 - 10.2 Ending a Task

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–156.4.1.3 Editing LabelsType in the new label and click on: OK

Strany 42 - 10–4 Rev. 0

SDM-300 Modem Screens MiniMAC Rack Management System6–16 Rev. 06.4.1.4 Acknowledging Command AcceptThe ACKNOWLEDGE COMMAND ACCEPTED screen will appear

Strany 43 - 9.1 Satellite Modems

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–176.4.1.5 Checking the Label Change on the ScreenObserve the device name has been update

Strany 44 - 9.1.1.1 Commands Menu

SDM-300 Modem Screens MiniMAC Rack Management System6–18 Rev. 06.4.2 Configure – Alarm SetupTo configure the alarms for this device, select CONFIGURE

Strany 45 - 9.1.1.2 Interface Commands

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–196.4.2.1 Setting Minor, Major, or Neither AlarmsEach fault/alarm can be set individuall

Strany 46 - Rev. 0 9–5

Rev. 0A–1AAppendix A. SYSTEM SETUPSPREADSHEETThis appendix describes the preparation of creating an EXCEL Spreadsheet. Thefollowing subjects with the

Strany 47 - 9–6 Rev. 0

SDM-300 Modem Screens MiniMAC Rack Management System6–20 Rev. 06.4.2.2 Saving Alarm Setup ChangesAfter completion, the user must exit and save the cha

Strany 48 - 9.1.2.1 Faults Alarm Screen

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–216.5 Polling MenusThe POLLING menus include ONLINE or FORCE.6.5.1 Polling – OnlineThe O

Strany 49 - 9.1.3.1 Modulator Commands

SDM-300 Modem Screens MiniMAC Rack Management System6–22 Rev. 06.6 Status MenuAllows the user to request various status information about the modem. S

Strany 50 - Rev. 0 9–9

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–236.6.1.1 Equipment Type Command Accepted ResponseThis screen will appear with the EQUIP

Strany 51 - 9.1.3.3 Faults/Alarms Screen

SDM-300 Modem Screens MiniMAC Rack Management System6–24 Rev. 06.7 Commands MenusThe command menus allow the user to change parameters on the modem. T

Strany 52 - Rev. 0 9–11

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–256.7.2 Interface CommandsThe INTERFACE COMMANDS screens are used to set the interface co

Strany 53 - 9.2.1 SDC-400 Down Converter

SDM-300 Modem Screens MiniMAC Rack Management System6–26 Rev. 0To change a parameter, proceed as follows:Command ResponseSelect Interface parameter to

Strany 54 - Rev. 0 9–13

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–276.7.2.2 Interface2 – CommandsThe INTERFACE2 COMMANDS allow the user to configure:• ASYN

Strany 55 - 9–14 Rev. 0

SDM-300 Modem Screens MiniMAC Rack Management System6–28 Rev. 06.7.3 Modulator/Demodulator CommandsThe MODULATOR/DEMODULATOR COMMANDS are used to set

Strany 56

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–296.7.3.2 Demodulator CommandsThe DEMODULATOR COMMANDS Screen allows the user to configur

Strany 57 - 9.2.2 SDC-600 Up Converter

Rev. 0 B–1BAppendix B. CONFIGURING ALARMSThis appendix describes configuring alarms, default beeps, sound, and wave files.Subject Section No.Introduct

Strany 58 - Rev. 0 9–17

SDM-300 Modem Screens MiniMAC Rack Management System6–30 Rev. 06.7.4 AUPC/Drop & Insert Commands6.7.4.1 AUPC CommandsThe AUPC COMMANDS allows the

Strany 59 - 9.3 Satellite Switches

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–316.7.4.2 Remote AUPC CommandsThe REMOTE AUPC COMMANDS allows the user to configure or ch

Strany 60 - Rev. 0 9–19

SDM-300 Modem Screens MiniMAC Rack Management System6–32 Rev. 06.7.4.3 D&I CommandsThe D&I COMMANDS Screen is used to set the D&I channel

Strany 61 - 9–20 Rev. 0

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–336.7.5 System/MUX PCB6.7.5.1 System CommandsThe System Command allows the user to confir

Strany 62 - Rev. 0 9–21

SDM-300 Modem Screens MiniMAC Rack Management System6–34 Rev. 06.7.5.2 MUX PCBThe modem requires a MUX overhead card to be installed for those command

Strany 63 - 9–22 Rev. 0

MiniMAC Rack Management System SDM-300 Modem ScreensRev. 0 6–356.8 Control Mode and Authority Menus6.8.1 Set Control ModeThe modem shall be in the R

Strany 64 - 9.3.2.4 Set Menu

SDM-300 Modem Screens MiniMAC Rack Management System6–36 Rev. 06.8.2 Command Authority WindowThe COMMAND AUTHORITY window shows the authority level o

Strany 65 - Transponder option

Options Menu MiniMAC Rack Management System5–2 Rev. 05.1 OptionsThe Options menu allows the user to access the following system features:• Logging• St

Strany 66 - Rev. 0 9–25

MiniMAC Rack Management System Options MenuRev. 0 5–35.1.1 Logging - Setting Up the Log ConfigurationFrom the Options menu, select Logging. The Event

Strany 67 - 9–26 Rev. 0

Options Menu MiniMAC Rack Management System5–4 Rev. 05.1.2 Saving Changes to the System Log ConfigurationWhen the power settings have been configured

Strany 68 - Rev. 0 9–27

Rev. 0 C–1CAppendix C. TROUBLESHOOTINGThis appendix describes the troubleshooting guide for the operation of the MiniMACSystem.Subject Section No.Trou

Strany 69 - 9–28 Rev. 0

MiniMAC Rack Management System Options MenuRev. 0 5–55.2 Options – Status LabelsStatus Labels are boxes that report status information on any device

Strany 70 - 9.4 Terminals

Options Menu MiniMAC Rack Management System5–6 Rev. 05.2.1 Insert LabelsThe Add Overview Label window will appear. The user must:Command ResponseSelec

Strany 71 - 9.4.2 Device Setup

MiniMAC Rack Management System Options MenuRev. 0 5–7The label will be locked in place and will display the status information of the device. Putthe c

Strany 72 - 9.4.3 KST-12000

Options Menu MiniMAC Rack Management System5–8 Rev. 05.2.2 Delete LabelsTo delete a label, click on the label to be deleted and go to Options, Labels,

Strany 73 - 9.5 RC-1150 LNA Controller

MiniMAC Rack Management System Options MenuRev. 0 5–95.3 Options – EditThe Edit Mode can be located in the main Overview Options menu and in the indiv

Strany 74 - 8.1 Status/Command Tab

Options Menu MiniMAC Rack Management System5–10 Rev. 05.3.2 Options – Edit Mode – Draw PropertiesClick on a device or group to be edited. The Draw Pr

Strany 75 - 8.1.1 Side A or B Status Tab

MiniMAC Rack Management System Options MenuRev. 0 5–115.3.3 Options – Edit Mode ColorThe color window is the same for all of the properties. Click on

Strany 76 - 8.2.1 Faults/Alarms Tab

Options Menu MiniMAC Rack Management System5–12 Rev. 05.3.4 Options – Edit Mode - FontFrom the Draw Properties window, the user also can select FONT

Strany 77 - 8.2.2 Alarm Setup Screen

MiniMAC Rack Management System Options MenuRev. 0 5–135.3.5 Options – Saving the EditWhen all devices have been edited, save edits in the Options men

Strany 78 - 8.3 Status

Options Menu MiniMAC Rack Management System5–14 Rev. 05.4 Options – System ColorsThe user has the ability to change the default color value of the va

Strany 79 - Rev. 0 8–7

Rev. 0 g–1GGlossary The following is a list of acronyms and abbreviations that may be found in this manual.Acronym/AbbreviationDefinitionACL Advanced

Strany 80 - NO RESPONSE

MiniMAC Rack Management System Options MenuRev. 0 5–155.5 Help MenuThe Help Menu will display the software version of the ILCNCS program that iscurren

Strany 81 - Rev. 0 8–9

Options Menu MiniMAC Rack Management System5–16 Rev. 0This page is intentionally left blank.

Strany 82 - 8.4.1 Commands – Backup Mode

User Menus MiniMAC Rack Management System4–2 Rev. 04.1 Logging On/Off the SystemAuthorized users must log On to the MiniMAC System in order to use th

Strany 83 - Rev. 0 8–11

MiniMAC Rack Management System User MenusRev. 0 4–3Command ResponseSelect USER NAMEType PasswordClick on OK4.1.2 Log OffTo log off, proceed as follows

Strany 84 - 8–12 Rev. 0

User Menus MiniMAC Rack Management System4–4 Rev. 04.2 Edit UsersNote: Only the authorized user as the SYSTEM user can add, change, or remove theserec

Strany 85

MiniMAC Rack Management System User MenusRev. 0 4–5Command ResponseSelect Edit UsersSelect AddType (USER NAME field) Log On name of the user (12 chara

Strany 86 - 7.1.1 View – Overview

User Menus MiniMAC Rack Management System4–6 Rev. 0The system will notify user that the record has been modified. Click on: OK.

Strany 87 - 7.1.2 View – Modem Faults

MiniMAC Rack Management System User MenusRev. 0 4–74.2.2 Deleting UsersTo remove a user, proceed as follows:Command ResponseSelect Edit UsersHighlight

Strany 88 - 7.2.1 Lock Labels

User Menus MiniMAC Rack Management System4–8 Rev. 04.3 Change PasswordTo EDIT PASSWORD screen, proceed as follows.

Strany 89 - 7.2.3 Alarm Setup – Set All

MiniMAC Rack Management System User MenusRev. 0 4–9Command ResponseSelect Edit UserSelect Change PasswordHighlight User record to be modifiedType User

Strany 90 - 7.3.2 Polling – Force

Rev. 0 i–1IIndex Acknowledge Command Accepted Response, 7–34Acknowledging All COM Alarms, 7–34Acknowledging All Device Alarms, 3–8Acknowledging Comman

Strany 91 - 7.4 Status - Menu

User Menus MiniMAC Rack Management System4–10 Rev. 0This page is intentionally left blank.

Strany 92 - Rev. 0 7–9

MiniMAC Rack Management System Alarms MenusRev. 03–23.1 View Latest AlarmTo view the latest alarms:Command ResponseSelect ALARMS drop down menuClick

Strany 93 - 7.5.1 Commands – Modulator

Alarms Menus MiniMAC Rack Management SystemRev. 03–33.1.1 Stored NumbersThe default number of stored alarms is zero. To change the number of stored al

Strany 94 - 7.5.2 Commands – Demodulator

MiniMAC Rack Management System Alarms MenusRev. 03–43.1.2 Changing Numbered StoredEnter the new number of stored alarms in the LIST SIZE ENTRY box an

Strany 95

Alarms Menus MiniMAC Rack Management SystemRev. 03–53.1.3 Returning to the Overview ScreenTo return to the OVERVIEW Screen, proceed as follows:Comman

Strany 96 - Rev. 0 7–13

MiniMAC Rack Management System Alarms MenusRev. 03–63.1.4 Viewing Stored AlarmsUpon subsequent entries into the ALARMS, VIEW LATEST ALARMS, from the

Strany 97 - 7–14 Rev. 0

Alarms Menus MiniMAC Rack Management SystemRev. 03–73.2 Acknowledging All Device AlarmsWhen a device has a fault or alarm, the MiniMAC will display a

Strany 98 - Rev. 0 7–15

MiniMAC Rack Management System Alarms MenusRev. 03–83.3 Acknowledging All COMM AlarmsWhen communications to a device is detected, the MiniMAC will di

Strany 99

Alarms Menus MiniMAC Rack Management SystemRev. 03–9

Strany 100 - Rev. 0 7–17

MiniMAC Rack Management System Alarms MenusRev. 03–103.4 Default Beep SetupIf the user desires the system to Beep upon Faults, Alarms, or Communicati

Strany 101 - 7–18 Rev. 0

Index MiniMAC Rack Management Systemi–2 Rev. 0Modulator/Demodulator Commands, 9–25MUX PCB, 6–1, 6–28, 9–5, 9–20Opening the COM Window, 6–2, 6–24, 6–33

Strany 102 - Rev. 0 7–19

Alarms Menus MiniMAC Rack Management SystemRev. 03–113.5 Alarm SoundFor the Default Beep to operate, the user must also set the Alarm Sound – Enable,w

Strany 103

MiniMAC Rack Management System Alarms MenusRev. 03–12This page is intentionally left blank.

Strany 104

MiniMAC Rack Management System System Menus2–2Rev. 02.1 System-Report GeneratorThe report generator stores all system activities. To open the report g

Strany 105 - 7.5.3.5 Modem Priority

System Menus MiniMAC Rack Management SystemRev. 0 2–32.2 Viewing the System LogA data log is maintained on device commands, changes in configuration,

Strany 106 - 7.5.3.6 Modem Online Delay

MiniMAC Rack Management System System Menus2–4Rev. 02.2.1 Filtering the LogTo filter SYSTEM LOG data, proceed as follows:Command ResponseSelect ViewC

Strany 107 - 7.5.3.7 D&I G.703 Data

Overview Screen MiniMAC Rack Management System1–2 Rev. 01.1 Path to ILCNCSStart MiniMAC Program as follows:Path: Start\Programs\ILCNCSNote: Double-cl

Strany 108 - 7.5.3.8 External Clock

MiniMAC Rack Management System Overview ScreenRev. 0 1–31.1.1 MiniMAC Main ScreenEach MiniMAC system is application-specific, so the appearance of th

Strany 109 - 7.5.3.9 Insert Data Input

Overview Screen MiniMAC Rack Management System1–4 Rev. 01.2 Viewing the Rack GroupsThis group or rack is connected to COMM Port 3.The user can view a

Strany 110 - 7.5.4 System Configuration

MiniMAC Rack Management System Overview ScreenRev. 0 1–51.2.2 C-Band Converter RackThis group or rack is connected to COMM Port 4.The second group o

Strany 111 - 7–28 Rev. 0

Overview Screen MiniMAC Rack Management System1–6 Rev. 01.2.3 CST-5000 RackThis group or rack is connected to COMM Port 5.The third group or rack on t

Strany 113 - 7–30 Rev. 0

Glossary MiniMAC Rack Management Systemg–2 Rev. 0IND IndependentIRQ Interrupt RequestISA Industry Standard ArchitectureLED Liquid Emitter DiodeLPT Loc

Strany 114 - Rev. 0 7–31

MiniMAC Rack Management System Overview ScreenRev. 0 1–71.2.4 SMS-7000 Switch RackThis group or rack is connected on COMM Port 6.The fourth group or

Strany 115 - 7–32 Rev. 0

Overview Screen MiniMAC Rack Management System1–8 Rev. 01.2.5 SMS-658 Switch RackThis group or rack is connected on COMM Port 7.This fifth group or r

Strany 116 - 7.6.1 Set Mode Remote

MiniMAC Rack Management System Overview ScreenRev. 0 1–91.2.6 SMS-758 Switch RackThis group or rack is connected on COMM Port 8.The sixth group or r

Strany 117 - 7–34 Rev. 0

Overview Screen MiniMAC Rack Management System1–10 Rev. 01.2.7 Remote Site 1This group or rack is connected on COMM Port 9.The seventh group or rack i

Strany 118 - 7.6.3 Mode – M:N

MiniMAC Rack Management System Overview ScreenRev. 0 1–111.3 Opening the COMM WindowLocate the Task Bar across the bottom of the screen. Observe tha

Strany 119 - 7.6.4 Mode – Switch DEP/IND

Overview Screen MiniMAC Rack Management System1–12 Rev. 01.3.1 Viewing Incoming and Outgoing MessagesAll devices in the system that are ONLINE are be

Strany 120 - 7.7 Command Authority

Warranty PolicyThis Adaptive Broadband product is warranted against defects in material andworkmanship for a period of one year from the date of shipm

Strany 121 - 7–38 Rev. 0

Rev. 0 iPrefaceAbout this ManualNote: Effective April 29, 1999, California Microwave, EFData, changed its name toAdaptive Broadband to reflect its cur

Strany 122

Preface MiniMAC Rack Management Systemii Rev. 0Recommended Standard DesignationsRecommended Standard (RS) Designations have been superseded by the new

Strany 123 - 6.1 Modem Control Screens

MiniMAC Rack Management System PrefaceRev. 0 iiiCustomer SupportContact the Adaptive Broadband Customer Support Department for:• Product support• Info

Strany 124 - 6.2.1 Modulator/Demodulator

Troubleshooting MiniMAC Rack Management SystemC–2 Rev. 0C.1 TroubleshootingRefer to if the MiniMAC Program runs but does not operate properly or gives

Strany 125 - 6.2.2 Interface Tab

Preface MiniMAC Rack Management Systemiv Rev. 0This page is intentionally left blank.

Strany 126 - 6.2.3 AUPC/D&I Tab

Rev. 0 vTable of ContentsCHAPTER 1. OVERVIEW SCREEN...1–11.1 Path to ILCNCS...

Strany 127 - 6.3.1 View – Overview

Table of Contents MiniMAC Rack Management Systemvi Rev. 03.4 Default Beep Setup...

Strany 128 - 6.3.2 View – Fault Screens

MiniMAC Rack Management System Table of ContentsRev. 0 vii6.4.1 Configure Lock Labels...

Strany 129

Table of Contents MiniMAC Rack Management Systemviii Rev. 07.4 Status - Menu ...

Strany 130 - 6.3.3 View - Stored Faults

MiniMAC Rack Management System Table of ContentsRev. 0 ixCHAPTER 9. OTHER DEVICES...

Strany 131 - Rev. 0 6–11

Table of Contents MiniMAC Rack Management Systemx Rev. 0APPENDIX B. CONFIGURING ALARMS...

Strany 132 - 6.4.1 Configure Lock Labels

MiniMAC Rack Management System TroubleshootingRev. 0 C–3Figure C-1. Device Communication ErrorThe Timeout Time for each available COMM port is report

Strany 133 - Rev. 0 6–13

Troubleshooting MiniMAC Rack Management SystemC–4 Rev. 0C.2 Debugging the ServicesWhen necessary to troubleshoot the MiniMAC program, use the DEBUG co

Strany 134 - 6–14 Rev. 0

MiniMAC Rack Management System TroubleshootingRev. 0 C–5C.2.1 Saving Debug to a FileFor customer support to evaluate the problem, the debug informati

Strany 135 - 6.4.1.3 Editing Labels

Troubleshooting MiniMAC Rack Management SystemC–6 Rev. 0When a failure occurs, close all tasks, including the Debug Command using the Task Manager.Ope

Strany 136 - 6–16 Rev. 0

MiniMAC Rack Management System TroubleshootingRev. 0 C–7C.3 Using the COMM WindowCommunication between the MiniMAc and devices can be monitored in th

Strany 137 - Rev. 0 6–17

Troubleshooting MiniMAC Rack Management SystemC–8 Rev. 0This page is intentionally left blank.

Strany 138 - 6–18 Rev. 0

Configuring Alarms MiniMAC Rack Management SystemB–2 Rev. 0B.1 IntroductionThe alarms setting is set to a default beep condition. When a fault, alarm,

Strany 139 - MAJOR, or NEITHER (NONE)

MiniMAC Rack Management System Configuring AlarmsRev. 0B–3B.2 Configuring AlarmsB.2.1 Alarm Sound Setup – EnableTo configure the MiniMAC to play atta

Strany 140 - 6–20 Rev. 0

Copyright © Comtech EFData, 2000.All rights reserved.Printed in the USA.Comtech EFData, 2114 West 7th Place, Tempe, Arizona 85281 USA, (480) 333.2200,

Strany 141 - 6.5.2 Polling – Force

Configuring Alarms MiniMAC Rack Management SystemB–4 Rev. 0B.2.2 Attaching System Wave FilesTo attach wave files to Alarms and Communication Alarms,

Strany 142 - 6.6 Status Menu

MiniMAC Rack Management System Configuring AlarmsRev. 0B–5To select a COMM Alarm wave file, click on the WAV button to the right of COMMALARM wave fil

Strany 143 - Rev. 0 6–23

Configuring Alarms MiniMAC Rack Management SystemB–6 Rev. 0Select an Alarm wave file in the same manner.Notice the path to the right of each alarm con

Strany 144 - 6.7.1 SDM-300 Commands

MiniMAC Rack Management System Configuring AlarmsRev. 0B–7B.3 Attaching Device Wave FilesAttaching a device alarm is similar to attaching a system wa

Strany 145 - 6.7.2.1 Interface1 – Commands

Configuring Alarms MiniMAC Rack Management SystemB–8 Rev. 0B.3.2 Alarm Setup Selecting a Wave FileSelect the desired wave file and click on Open. Onc

Strany 146

MiniMAC Rack Management System Configuring AlarmsRev. 0B–9B.3.3 Saving the Alarm Setup ChangesContinue to configure Alarms until all desired Alarms h

Strany 147 - 6.7.2.2 Interface2 – Commands

Configuring Alarms MiniMAC Rack Management SystemB–10 Rev. 0This page is intentionally left blank.

Strany 148 - 6.7.3.1 Modulator Commands

System Setup Spreadsheet MiniMAC Rack Management SystemRev. 0A–2Figure A-1 is an example of the system spreadsheet. All communication, computer, andde

Strany 149 - 6.7.3.2 Demodulator Commands

MiniMAC Rack Management System System Setup SpreadsheetRev. 0A–3Figure A-1. System Spreadsheet

Strany 150 - 6.7.4.1 AUPC Commands

System Setup Spreadsheet MiniMAC Rack Management SystemRev. 0A–4This page is intentionally left blank.

Strany 151 - 6.7.4.2 Remote AUPC Commands

Rev. 0 1–11Chapter 1. OVERVIEW SCREENThis chapter describes the main OVERVIEW Screen of the ILCNCS MiniMAC Program.The user can access all the racks o

Strany 152 - 6.7.4.3 D&I Commands

Ending the Program with Task Manager MiniMAC Rack Management System10–2 Rev. 010.1 Using the Task ManagerThe proper procedure to end the program is

Strany 153 - 6.7.5.1 System Commands

MiniMAC Rack Management System Ending the Program with Task ManagerRev. 0 10–310.2 Ending a TaskHighlight the program ILCNCS and click on End Task.

Strany 154 - 6.7.5.2 MUX PCB

Ending the Program with Task Manager MiniMAC Rack Management System10–4 Rev. 0

Strany 155 - 6.8.1 Set Control Mode

Other Devices MiniMAC Rack Management System9–2 Rev. 09.1 Satellite ModemsOther EFData Modem Device Screens are similar to the SDM-300 described inCha

Strany 156 - 6–36 Rev. 0

MiniMAC Rack Management System Other DevicesRev. 0 9–39.1.1.1 Commands MenuThe COMMANDS Menu includes; Remote, Interface, Modulator, and Demodulator.

Strany 157 - 5.1 Options

Other Devices MiniMAC Rack Management System9–4 Rev. 09.1.1.2 Interface CommandsTo access the Interface Commands, select COMMANDS and click on INTERFA

Strany 158 - Rev. 0 5–3

MiniMAC Rack Management System Other DevicesRev. 0 9–59.1.1.3 Modulator/Demodulator CommandsTo access MODULATOR/DEMODULATOR COMMANDS, select Commands

Strany 159 - 5–4 Rev. 0

Other Devices MiniMAC Rack Management System9–6 Rev. 09.1.2 SDM-309 Satellite ModemThe SDM-309 IBS Modem Screen functions like the SDM-308-4 Modem Co

Strany 160 - 5.2 Options – Status Labels

MiniMAC Rack Management System Other DevicesRev. 0 9–79.1.2.1 Faults Alarm ScreenTo view the FAULTS/ALARMS screen click on any of the faults status bu

Strany 161 - 5.2.1 Insert Labels

Other Devices MiniMAC Rack Management System9–8 Rev. 09.1.3 SDM-308-5 Satellite ModemThe SDM-308-5 Drop and Insert (D&I) Modem Control Screen dro

Strany 162 - Rev. 0 5–7

Rev. 0 2–12Chapter 2 SYSTEM MENUSThis chapter describes the system menu log. The following subjects with sectionnumbers are described in the chapter.S

Strany 163 - 5.2.2 Delete Labels

MiniMAC Rack Management System Other DevicesRev. 0 9–99.1.3.2 Drop and Insert CommandsFrom the DROP AND INSERT file folder, the user can set the foll

Strany 164 - 5.3.1 Options – Edit Mode

Other Devices MiniMAC Rack Management System9–10 Rev. 09.1.3.3 Faults/Alarms ScreenFrom the FAULTS/ALARMS file folder the user can:• View Active Fault

Strany 165 - 5–10 Rev. 0

MiniMAC Rack Management System Other DevicesRev. 0 9–119.1.4 SDM-8000, SDM-6000, and SDM-9000 Satellite ModemNote: The SDM-6000 and SDM-9000 function

Strany 166 - Rev. 0 5–11

Other Devices MiniMAC Rack Management System9–12 Rev. 09.2 Satellite Data Converters9.2.1 SDC-400 Down ConverterThe CONVERTER CONTROL screen is disp

Strany 167 - Properties of the label

MiniMAC Rack Management System Other DevicesRev. 0 9–139.2.1.1 Converter Status and Commands ScreensTo access the CONVERTER STATUS and COMMAND screen

Strany 168 - Rev. 0 5–13

Other Devices MiniMAC Rack Management System9–14 Rev. 0To change a parameter:1. For converter parameter information, refer to the appropriate installa

Strany 169 - 5.4 Options – System Colors

MiniMAC Rack Management System Other DevicesRev. 0 9–159.2.1.2 Hexadecimal Digital MaskingDigital masking parameters appear on the MiniMAC screen in

Strany 170 - 5.5 Help Menu

Other Devices MiniMAC Rack Management System9–16 Rev. 09.2.2 SDC-600 Up ConverterThe CONVERTER CONTROL screen is displayed by choosing a converter bu

Strany 171 - 5–16 Rev. 0

MiniMAC Rack Management System Other DevicesRev. 0 9–17To change a parameter:1. For converter parameter information, refer to the appropriate installa

Strany 172 - 4.1.1 Log On

Other Devices MiniMAC Rack Management System9–18 Rev. 09.3 Satellite Switches9.3.1 RSU-503/-503L Radio Terminal Redundancy SwitchThe RSU-503 RFT Swit

Strany 173 - 4.1.2 Log Off

Rev.03–13Chapter 3 ALARMS MENUSThis chapter describes the alarm options.Subject Section No.View Latest AlarmStore NumbersChanging Store NumbersAdding

Strany 174 - 4.2 Edit Users

MiniMAC Rack Management System Other DevicesRev. 0 9–199.3.2 SMS-301 1:1 Protection SwitchThe SMS-301 SWITCH CONTROL screen exhibits the front panel

Strany 175

Other Devices MiniMAC Rack Management System9–20 Rev. 09.3.2.1 Modulator/Demodulator CommandsThe modulator and demodulator commands allow the user to

Strany 176 - 4–6 Rev. 0

MiniMAC Rack Management System Other DevicesRev. 0 9–219.3.2.2 Configuration CommandsThe Configuration Commands screen allows the user to set the foll

Strany 177 - 4.2.2 Deleting Users

Other Devices MiniMAC Rack Management System9–22 Rev. 09.3.2.3 Load Modem Configuration CommandsThe Load Modem Configuration Command allows the user

Strany 178 - Password

MiniMAC Rack Management System Other DevicesRev. 0 9–239.3.2.4 Set MenuThe Set Menu screen allows the user to configure the switch functions including

Strany 179

Other Devices MiniMAC Rack Management System9–24 Rev. 09.3.3 SMS-658 Modem Protection SwitchThe SMS-658 Switch operates similar to SMS-7000 Switch. T

Strany 180 - 4–10 Rev. 0

MiniMAC Rack Management System Other DevicesRev. 0 9–259.3.3.1 Modulator Transponder CommandsNote: This function is available only for the SMS-658 sw

Strany 181 - 3.1 View Latest Alarm

Other Devices MiniMAC Rack Management System9–26 Rev. 0To change the assignment of a transponder:1. From the PRIME MOD column, choose the prime modula

Strany 182 - 3.1.1 Stored Numbers

MiniMAC Rack Management System Other DevicesRev. 0 9–279.3.3.2 Demodulator Transponder CommandsOn the [PRIME DEMODULATOR CONFIGURATION] screen, statu

Strany 183 - CANCEL procedure

Other Devices MiniMAC Rack Management System9–28 Rev. 09.3.4 SMS-758 Modem Protection SwitchThe SMS-758 Modem Protection Switch operates similar to

Strany 184 - Click on OVERVIEW SCREEN

Rev. 0 4–14Chapter 4 USER MENUSThis chapter describes user menus. The following subjects with section numbers aredescribed in the chapter.Subject Sect

Strany 185 - 3.1.4 Viewing Stored Alarms

MiniMAC Rack Management System Other DevicesRev. 0 9–299.4 Terminals9.4.1 RFT-500 Radio Frequency TerminalThe RFT-500 is the C-Band Radio Frequency T

Strany 186

Other Devices MiniMAC Rack Management System9–30 Rev. 09.4.2 Device SetupTo view the device setup screen click on the Device Setup button. From the De

Strany 187

MiniMAC Rack Management System Other DevicesRev. 0 9–319.4.3 KST-12000The KST-12000 is the Ku-Band Radio Frequency Terminal (RFT) and operates similar

Strany 188

Other Devices MiniMAC Rack Management System9–32 Rev. 09.5 RC-1150 LNA ControllerThe RC-1150 or RC-1250 LNA Controller allows the user to switch betwe

Strany 189 - 3.4 Default Beep Setup

V2200 Dual Converter Screens MiniMAC Rack Management System8–2 Rev. 08.1 Status/Command TabThe V2200 DUAL CONVERTER CONTROL Screen displays fully-func

Strany 190 - 3.5 Alarm Sound

MiniMAC Rack Management System V2200 Dual Converter ScreensRev. 0 8–38.1.1 Side A or B Status TabThe Side A or B Channel Status Tab displays the prog

Strany 191

V2200 Dual Converter Screens MiniMAC Rack Management System8–4 Rev. 08.2 Alarms/Faults8.2.1 Faults/Alarms TabThe FAULT/ALARM TAB displays the active a

Strany 192 - 2.1 System-Report Generator

MiniMAC Rack Management System V2200 Dual Converter ScreensRev. 0 8–58.2.2 Alarm Setup ScreenFrom the CONFIGURE drop-down menu, select ALARM SETUP to

Strany 193 - 2.2 Viewing the System Log

V2200 Dual Converter Screens MiniMAC Rack Management System8–6 Rev. 08.3 Status8.3.1 Status – Channel StatusThe status information that can be reques

Strany 194 - 2.2.1 Filtering the Log

MiniMAC Rack Management System V2200 Dual Converter ScreensRev. 0 8–78.3.2 Status – Equipment TypeTo verify communication to the converter, select Eq

Strany 195 - 1.1 Path to ILCNCS

Rev. 0 5–15Chapter 5 OPTIONS MENUThis chapter describes the options menu. The following subjects with section numbersare described in the chapter.Subj

Strany 196 - 1.1.1 MiniMAC Main Screen

V2200 Dual Converter Screens MiniMAC Rack Management System8–8 Rev. 08.3.3 Acknowledging Command ResponseThe COMMAND ACCEPTED MESSAGE window will appe

Strany 197 - 1.2 Viewing the Rack Groups

MiniMAC Rack Management System V2200 Dual Converter ScreensRev. 0 8–98.4 V2200 Dual Converter CommandsIn order to TX commands to the converters the V

Strany 198 - 1.2.2 C-Band Converter Rack

V2200 Dual Converter Screens MiniMAC Rack Management System8–10 Rev. 08.4.1 Commands – Backup ModeTo put the converter in the backup mode, the V2200

Strany 199 - 1.2.3 CST-5000 Rack

MiniMAC Rack Management System V2200 Dual Converter ScreensRev. 0 8–118.4.2 Commands – Prime Converter OnlineWhen Backup Mode equals manual, the user

Strany 200 - 1.2.4 SMS-7000 Switch Rack

V2200 Dual Converter Screens MiniMAC Rack Management System8–12 Rev. 08.4.3 Commands – Setup SettingsRefer to the Installation and Operation Manual o

Strany 201 - 1.2.5 SMS-658 Switch Rack

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–2 Rev. 0Verify Active Mode Configuration Load Prime ModemLoad All Active ModemsLoad

Strany 202 - 1.2.6 SMS-758 Switch Rack

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–37.1 Switch Control ScreenTo display the SWITCH CONTROL Screen, click on th

Strany 203 - 1.2.7 Remote Site 1

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–4 Rev. 07.1.2 View – Modem FaultsTo view the switch faults related to the prime an

Strany 204 - 1.3 Opening the COMM Window

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–57.2 Configure Menus7.2.1 Lock LabelsThe LOCK LABELS menu functions similar

Strany 205 - 1–12 Rev. 0

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–6 Rev. 07.2.3 Alarm Setup – Set AllThe ALARM SETUP window will appear with a list

Strany 206 - Disclaimer

Rev. 0 6–16Chapter 6 SDM-300 MODEMThis chapter describes the SDM-300 menus for the prime and backup modems. Thefollowing subjects with the section num

Strany 207 - Metric Conversion

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–77.3 PollingThe POLLING menus include ONLINE or FORCE.7.3.1 Polling – Onlin

Strany 208 - Related Documents

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–8 Rev. 07.4 Status - MenuAllows the user to request various status information abo

Strany 209 - Customer Support

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–97.4.1 Status Response AcknowledgmentTo poll Equipment Type, select: STATUS\

Strany 210

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–10 Rev. 07.5 CommandsThe COMMANDS menu allows the user to configure switch commands

Strany 211 - Table of Contents

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–117.5.1.1 Commands – Backup ModulatorUse the BACKUP MODULATOR screen to swi

Strany 212

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–12 Rev. 0To switch a modulator/demodulator to Backup, proceed as follows:Command Re

Strany 213 - Rev. 0 vii

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–137.5.3 Commands – Switch ConfigurationUse the SWITCH CONFIGURATION screen

Strany 214

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–14 Rev. 07.5.3.1 Switch Configuration ScreenTo access the desired switch configurat

Strany 215 - Rev. 0 ix

MiniMAC Rack Management System SMS-7000 Protection Switch ScreensRev. 0 7–157.5.3.2 Prime Modulator ConfigurationOn the PRIME MODULATOR CONFIGURATION

Strany 216

SMS-7000 Protection Switch Screens MiniMAC Rack Management System7–16 Rev. 0To check the status of one or more modulators:1. Click on each MOD X field