Operation C5/K1/K3 Integrated Satellite Terminal System
4–10 Rev. 0
TX POWER LEVEL C-Band - Programs the modulator output power level from
+25.0 to +39.0 dBm.
Ku-Band K1 - Programs the modulator output power level from
+17.0 to + 30.0 dBm.
Ku-Band K3 - Programs the modulator output power level from
+22.0 to + 35.0 dBm.
An offset can be added through the Utility menu to remove losses or
gains in the system.
Upon entry, the current transmitter power level is displayed with the
flashing cursor on the first character. Press [$] or [%] to increase or
decrease the output power level in 0.1 dBm steps. Press [ENTER] to
execute the change.
Note: The front panel display may be changed in the power offset
utility. Using that function does not change the actual output power
level.
SCRAMBLER Programs the scrambler on or off.
Upon entry, the status of the scrambler is displayed. Press [$] or [%] to
make the selection. Press [ENTER] to execute the change.
DIFF. ENCODER Programs the differential encoder on or off.
Upon entry, the status of the differential encoder is displayed. Press
[$] or [%] to make the selection. Press [ENTER] to execute the change.