Comtech-ef-data SDM-9600 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Comtech-ef-data SDM-9600. Comtech EF Data SDM-9600 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
NetPerformer® SDM-9600 with SDM-9606 Blades
Hardware Installation Guide
Zobrazit stránku 0
1 2 3 4 5 6 ... 93 94

Shrnutí obsahu

Strany 1 - Hardware Installation Guide

NetPerformer® SDM-9600 with SDM-9606 BladesHardware Installation Guide

Strany 3 - Contents

1Memotec Inc. 1-1Preface

Strany 4

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-2 Memotec Inc.1.1 About this DocumentThis document, NetPerformer® SDM-9600 Hardware Install

Strany 5

PrefaceMemotec Inc. 1-31.2 AudienceThis document is intended for use by NetPerformer system administrators as well as technicians who are qualified

Strany 6

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-4 Memotec Inc.1.3 Product Overview1.3.1 SDM-9600 ChassisThe NetPerformer SDM-9600 is a high

Strany 7 - List of Figures

PrefaceMemotec Inc. 1-51.3.3 NetPerformer SoftwareThe basic software set provides support of PowerCell voice and data (including legacy user data) a

Strany 8

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-6 Memotec Inc.1.4 Related DocumentsNOTE: All of the documents listed here are available on

Strany 9 - List of Tables

PrefaceMemotec Inc. 1-71.4.3 TrainingWe offer a variety of classes to reduce your learning curve and make your employees more productive. Students l

Strany 10 - Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-8 Memotec Inc.1.5 Technical SupportMemotec Technical Support is designed to meet your full

Strany 11 - Memotec Inc. 1-1

PrefaceMemotec Inc. 1-9only on the nameplate on the underside of the blade (see Figure 1-1).1.5.4 Checking the Contents of Your Product PackageCAUTI

Strany 12 - 1.1 About this Document

COPYRIGHTS AND DISCLAIMERSPublished Date: October 2013Document # 1659 current revision tracker artf3363This publication contains information proprieta

Strany 13 - 1.2 Audience

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-10 Memotec Inc.1.5.5 Returning an SDM-9600 Chassis or SDM-9606 BladeIf you need to return t

Strany 14 - 1.3 Product Overview

PrefaceMemotec Inc. 1-111.6 Sales ContactsTo order NetPerformer units, DSP modules, cables and optional parts, contact Memotec Inc. or your NetPerfo

Strany 15 - 1.3.3 NetPerformer Software

SDM-9600 with SDM-9606 Blades Hardware Installation Guide1-12 Memotec Inc.

Strany 16 - 1.4 Related Documents

2Memotec Inc. 2-1Compliance Information

Strany 17 - 1.4.3 Training

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-2 Memotec Inc.2.1 Regulatory – Compliance and Agency ApprovalThese products comply with or

Strany 18 - 1.5 Technical Support

Compliance InformationMemotec Inc. 2-32.2 Compliance and Regulatory Statements2.2.1 EU Directive 1999/5DECLARATION OF CONFORMITYWe declare under our

Strany 19

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-4 Memotec Inc.• MEMOTEC vakuuttaa täten että NetPerformer tyyppinen laite on direktiivin 19

Strany 20 - 1-10 Memotec Inc

Compliance InformationMemotec Inc. 2-5• Šiuo MEMOTEC deklaruoja, kad šis NetPerformer atitinka esminius reika-lavimus ir kitas 1999/5/EB Direktyvos

Strany 21 - 1.6 Sales Contacts

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-6 Memotec Inc.2.2.3 Intent of Use and Network Compatibility2.2.4 EN55022 and CISPR22 Warnin

Strany 22 - 1-12 Memotec Inc

Compliance InformationMemotec Inc. 2-72.2.6 FCC Part 15 StatementThis digital equipment has been tested and found to comply with the limits for a Cl

Strany 23 - Compliance Information

Memotec Inc.ContentsChapter 1: Preface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-8 Memotec Inc.2.3 Environmental Information2.3.1 Waste Electrical and Electronic Equipment

Strany 25 - 2.2.1 EU Directive 1999/5

Compliance InformationMemotec Inc. 2-92.3.2 Restriction of Hazardous Substances - RoHSRoHS - DECLARATION OF COMPLIANCEWe declare that the NetPerform

Strany 26 - 2-4 Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-10 Memotec Inc.2.3.3 Compliance to China RoHS䶵䶵⚗₼⦌ 5R+6(Compliance to China RoHS)䜘Ԧ਽〠(Par

Strany 27 - 2.2.2 Marking

Compliance InformationMemotec Inc. 2-112.4 Safety Warnings and PrecautionsWARNING:WarnungAvertissement2.5 Making Changes or ModificationsCAUTION:Any

Strany 28 - 2.2.5 FERRITES (EMI Filters)

SDM-9600 with SDM-9606 Blades Hardware Installation Guide2-12 Memotec Inc.

Strany 29 - 2.2.6 FCC Part 15 Statement

3Memotec Inc. 3-1Unpacking the SDM-9600

Strany 30 - 2.3 Environmental Information

SDM-9600 with SDM-9606 Blades Hardware Installation Guide3-2 Memotec Inc.3.1 Selecting a LocationTo ensure that the SDM-9600 functions properly, you s

Strany 31 - Memotec Inc. 2-9

Unpacking the SDM-9600Memotec Inc. 3-3• Maximum operating altitude: 4572 meters (15 000 feet)** NOTE:Above 3048 meters (10 000 feet) altitude the ma

Strany 32 - 䶵⚗₼⦌ 5R+6

SDM-9600 with SDM-9606 Blades Hardware Installation Guide3-4 Memotec Inc.- One crossover cable for each E1/T1 port that must provide a TE connection (

Strany 33 - WARNING:

4Memotec Inc. 4-1Hardware Installation

Strany 34 - 2-12 Memotec Inc

Memotec Inc.2.3.3 Compliance to China RoHS. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-102. 4 Safety Warnings and Precautions . . . . . .

Strany 35 - Unpacking the SDM-9600

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-2 Memotec Inc.4.1 About the Hardware InstallationHardware installation of the SDM-9600 invo

Strany 36 - 3.1 Selecting a Location

Hardware InstallationMemotec Inc. 4-34.2 Installing the SDM-9600 Chassis in a RackThe SDM-9600 chassis is designed with rackmount ears for installat

Strany 37 - 3.2 Preparing the Site

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-4 Memotec Inc.4.3 Installing or Upgrading the DSP ModulesFollow the procedure in this secti

Strany 38 - TE connection

Hardware InstallationMemotec Inc. 4-5You can increase the number of voice channels supported by upgrading the DSP module. Refer to “DSP Modules” on

Strany 39 - Hardware Installation

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-6 Memotec Inc.a. Locate the small metal clips that hold the DSP module into place at each s

Strany 40 - 4-2 Memotec Inc

Hardware InstallationMemotec Inc. 4-7b. Press the top edge down until the module snaps into place between the two metal clips at each end of the DSP

Strany 41 - Memotec Inc. 4-3

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-8 Memotec Inc.4.4 Hardware Strapping for E1 PortsThe E1/T1 interfaces on the SDM-9606 blade

Strany 42 - 4-4 Memotec Inc

Hardware InstallationMemotec Inc. 4-94.5 Installing a BladeThe SDM-9606 blades are installed in slots at the front of the SDM-9600 chassis. Up to 5

Strany 43 - 4.3.2 Installation Procedure

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-10 Memotec Inc.one of the ground lugs on the SDM-9600 chassis.2. Select an available blade

Strany 44 - 45° angle

Hardware InstallationMemotec Inc. 4-11• Press the handle back toward the front face of the blade.NOTE: The right card handle is equipped with a micr

Strany 45 - Memotec Inc. 4-7

Memotec Inc.5. 1 SDM-9600 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-25. 2 SDM-9606 Blade . . . . .

Strany 46 - 4-8 Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-12 Memotec Inc.4.6 Removing a BladeCaution: Blades must be removed with care. Use ESD proce

Strany 47 - 4.5 Installing a Blade

Hardware InstallationMemotec Inc. 4-135. Slide the blade the rest of the way out of the chassis.Caution: Do not expose the blade to a magnetic field

Strany 48

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-14 Memotec Inc.4.7 Installing the Filler PanelsTo limit electromagnetic interference and en

Strany 49 - Memotec Inc. 4-11

Hardware InstallationMemotec Inc. 4-154.8 Powering Up the Unit4.8.1 Connecting to the Power SourceNOTE: Information about the power input modules is

Strany 50 - 4.6 Removing a Blade

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-16 Memotec Inc.6. Connect the strip terminations of the harness wires to the -48 volt DC po

Strany 51 - Memotec Inc. 4-13

Hardware InstallationMemotec Inc. 4-17NOTE: If the OOS LED on the SDM-9606 blade stays amber, the unit may be faulty. Contact Technical Support for

Strany 52 - 4-14 Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-18 Memotec Inc.4.9 Connecting the Console TerminalA console cable kit (Part no. 161-1066-00

Strany 53 - 4.8 Powering Up the Unit

Hardware InstallationMemotec Inc. 4-19• Available console speeds are 1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600 and 115200 bps. The equipmen

Strany 54

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-20 Memotec Inc.4.9.3 Concerning HyperTerminal ConnectionsThe HyperTerminal communications

Strany 55

Hardware InstallationMemotec Inc. 4-214.10 Installing the Licensed Software OptionsExecute the Product License Status (PLS) command at the NetPerfor

Strany 56

Memotec Inc.7. 4 Network Management and Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-5Index . . . . . . . . . . . . . . . .

Strany 57

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-22 Memotec Inc.4.11 Connecting the LAN HubYou must provide a standard straight through Ethe

Strany 58

Hardware InstallationMemotec Inc. 4-234.12 Cleaning the Air FilterThe air filter in the SDM-9600 chassis should be verified on a regular basis and c

Strany 59 - 4.10.1 Software License Key

SDM-9600 with SDM-9606 Blades Hardware Installation Guide4-24 Memotec Inc.NOTE: If the air filter tray is difficult to remove, you can use the M3 rete

Strany 60 - 4.11 Connecting the LAN Hub

5Memotec Inc. 5-1Product Description

Strany 61 - 4.12 Cleaning the Air Filter

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-2 Memotec Inc.5.1 SDM-9600 Chassis5.2 SDM-9606 Blade5.3 Optional HardwareItem DetailsBase u

Strany 62 - 4-24 Memotec Inc

Product DescriptionMemotec Inc. 5-35.4 Base Unit ChassisFigure 5-1: Front View of the SDM-9600 Chassis Equipped with SDM-9606 Blades5 slotsfor blad

Strany 63 - Product Description

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-4 Memotec Inc.5.4.1 Physical Dimensions• Width (chassis only): 43.58 cm (17.16")• Wid

Strany 64 - 5.3 Optional Hardware

Product DescriptionMemotec Inc. 5-55.4.4 Fan UnitThe fan unit, including fans and an air filter module, is located on the right side of the SDM-9600

Strany 65 - 5.4 Base Unit Chassis

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-6 Memotec Inc.5.4.5 Air FilterThe air filter is:• Washable fabric• Velcro™-type adherence t

Strany 66 - 5.4.3 Power Input Modules

Product DescriptionMemotec Inc. 5-75.5 Blades for SDM-9600 Chassis5.5.1 SDM-9606 BladeThe SDM-9606 blade provides IP connectivity, E1/T1 universal d

Strany 67 - 5.4.4 Fan Unit

Memotec Inc.List of FiguresLocation of Product Numbering on the SDM-9600 DC Nameplate . . . . . . . . . . . . . . . . . . . . . . . . 1-9The SDM-9600

Strany 68 - 5.4.5 Air Filter

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-8 Memotec Inc.5.5.2 System Status LEDsThe following system status LEDs are located on the f

Strany 69 - 5.5.1 SDM-9606 Blade

Product DescriptionMemotec Inc. 5-95.6 Ethernet Ports5.6.1 Ports• 2 fully routed Ethernet IEEE 802.3 LAN interfaces• RJ-45 10/100BaseT connectors •

Strany 70 - 5.5.2 System Status LEDs

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-10 Memotec Inc.5.6.4 RJ-45 Connector for Ethernet LAN PortThe RJ-45 female connectors marke

Strany 71 - 5.6 Ethernet Ports

Product DescriptionMemotec Inc. 5-115.7 DSP ModulesOn the SDM-9606 blade the DSP processors digitize, process and compress voice signals, handle fax

Strany 72 - Pin No. Usage Description

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-12 Memotec Inc.products (SDM-9360, SDM-9380 and SDM-9585).

Strany 73 - 5.7 DSP Modules

Product DescriptionMemotec Inc. 5-135.8 Console Port5.8.1 PortOne PC-compatible console port:• RJ-45 female connector• TIA-232 (V.24) serial interfa

Strany 74 - 5-12 Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-14 Memotec Inc.5.8.3 RJ-45 Connector for Console PortThe RJ-45 female connector marked CSL

Strany 75 - 5.8 Console Port

Product DescriptionMemotec Inc. 5-155.9 E1/T1 Digital Interfaces5.9.1 Ports6 digital ports are built into front of the SDM-9606 blade.Each port has:

Strany 76

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-16 Memotec Inc.5.9.2 E1/T1 Port Status LEDsThree LEDs are located to the left of each digit

Strany 77 - 5.9 E1/T1 Digital Interfaces

Product DescriptionMemotec Inc. 5-175.9.4 Adaptor Cable• RJ-48M to E1-75 dual BNC adaptor cable (Ordering part number: AG2CA0001)• Installed between

Strany 79 - 5.9.4 Adaptor Cable

SDM-9600 with SDM-9606 Blades Hardware Installation Guide5-18 Memotec Inc.5.9.5 E1/T1 CablesYou must provide an RJ-48 cable for each E1/T1 connection.

Strany 80 - 5.9.5 E1/T1 Cables

6Memotec Inc. 6-1Troubleshooting Tips

Strany 81 - Troubleshooting Tips

SDM-9600 with SDM-9606 Blades Hardware Installation Guide6-2 Memotec Inc.6.1 Symptoms, Problems, and SolutionsSymptom Possible Problem SolutionUnit do

Strany 82

Troubleshooting TipsMemotec Inc. 6-3Console terminal displays unreadable charactersConsole terminal was not set to the default console speed before

Strany 83

SDM-9600 with SDM-9606 Blades Hardware Installation Guide6-4 Memotec Inc.

Strany 84 - 6-4 Memotec Inc

7Memotec Inc. 7-1Networking Features

Strany 85 - Networking Features

SDM-9600 with SDM-9606 Blades Hardware Installation Guide7-2 Memotec Inc.7.1 GSM A-bis/A-ter Optimization• Voice:-FR- EFR-HR- AMR 16K- AMR 8K• Data:-

Strany 86 - 7-2 Memotec Inc

Networking FeaturesMemotec Inc. 7-37.2 Voice ChannelsNOTE: Available with PowerCell transport (global Voice transport method parameter set to PowerC

Strany 87 - 7.2 Voice Channels

SDM-9600 with SDM-9606 Blades Hardware Installation Guide7-4 Memotec Inc.7.3 Network Connections• Circuits: leased, switched, public and private Frame

Strany 88 - 7.3 Network Connections

Networking FeaturesMemotec Inc. 7-57.4 Network Management and Security• SNMP management and monitoring via SNMP-based network management sys-tem lik

Strany 89 - Memotec Inc. 7-5

Memotec Inc.List of TablesCompatible Telecom Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 90 - 7-6 Memotec Inc

SDM-9600 with SDM-9606 Blades Hardware Installation Guide7-6 Memotec Inc.

Strany 91

SDM-9600 with SDM-9606 Blades Hardware Installation Guide Index-7IndexAAccess methods 3-3ACT LEDon LAN port 5-9Air filtercleaning 4-23ALARM LED 5-8Aut

Strany 92

8-Index Memotec Inc.ALARM 5-8chassis 5-4D-CH 5-16E1/T1 ports 5-16H/S 5-8interpreting problems 6-1LAN port 5-9LINK 5-9on SDM-9606 digital ports 5-16OOS

Strany 93

SDM-9600 with SDM-9606 Blades Hardware Installation Guide Index-9

Strany 94 - REACH FURTHER. OFFER MORE

REACH FURTHER. OFFER MORE.Contact Memotec:tel.: +1-514-738-4781e-mail: [email protected] Henri Bourassa Blvd. West Montreal, Quebec | Ca

Příbuzné modely SDM-9606

Komentáře k této Příručce

Žádné komentáře