Part Number MN-MCED100 Revision 1 IMPORTANT NOTE: The information contained in this document supersedes all previously published informati
MCED-100 MetaCarrier Embedding Device Revision 1 Table of Contents MN-MCED100 viii Thispageisintentionallyblank
ix PREFACE About this Manual ThismanualprovidesinstallationandoperationinformationfortheComtechEFData MCED‐100MetaCarrier® Embedding
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 x Metric Conversion Metric conversion information is located on the insi
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xi • UNPRESSURIZEDALTITUDESOFMORETHAN2000METRES(6561.7FEET).• EXCE
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xii European Union Low Voltage Directive (LVD) (2006/95/EC) Symbol Description
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xiii Warranty Policy ComtechEFData productsarewarranted againstdefectsi
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xiv Thewarrantyexclud esanyrespons ibilitybyComtechEFDataCorporationf
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xv Getting Help Contacting Comtech EF Data ContactComtechEFDatafor:• Te
MCED-100 MetaCarrier Embedding Device Revision 1 Preface MN-MCED100 xvi Returning a Product for Upgrade or Repair Step Task1GototheComtechEF
1–1 Chapter 1. INTRODUCTION 1.1 Overview Figure 1-1. MCED-100 MetaCarrier Embedding Device ComtechEFData’sMCED‐100MetaCarrier®EmbeddingDev
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–2 1.2 Functional Description Figure 1-2. MCED-100 Connection Exampl
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–3 TheentireCIDmessageisbrokeninto18packetscontaining12 2bits(
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–4 3. Performa“hard”rebootoftheMCED‐100–Manuallypower‐cyclethe
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–5 • 10MHzReference• FrequencyShiftKeying(FSK)modulationforcont
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–6 1.3 MCED-100 Features 1.3.1 Physical Description The MCED‐100 is c
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–7 1.3.3 MCED-100 Physical Features 1.3.3.1 Front Panel Figure 1
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–8 1.3.3.2 Rear Panel PROPERGROUNDINGPROTECTIONISREQUIRED.Theequi
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–9 1.4 MCED-100 Specifications 1.4.1 Product Feature Specifications Spec
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–10 Specification Description Harmonics and Spurious L-Band -60dBc/4 kHz
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–11 1.4.2 Standard Assemblies Assembly Description Where Installed PL-0
Copyright © 2012 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.22
MCED-100 MetaCarrier Embedding Device Revision 1 Introduction MN-MCED100 1–12 Notes:
2–1 Chapter 2. INSTALLATION 2.1 Unpacking and Inspecting the Shipment The MCED‐100 MetaCarrier® Embedding Device, its Installation and Operat
MCED-100 MetaCarrier Embedding Device Revision 1 Installation MN-MCED100 2–2 Once opened, inspect the shipment: Step Task 1 Keep all shipping ma
MCED-100 MetaCarrier Embedding Device Revision 1 Installation MN-MCED100 2–3 Feature Description1 CustomRackEnclosure2MCE
MCED-100 MetaCarrier Embedding Device Revision 1 Installation MN-MCED100 2–4 2.2.1 Installing the Optional Rear-Mounting Support Brackets Kit
MCED-100 MetaCarrier Embedding Device Revision 1 Installation MN-MCED100 2–5 ToolsneededtoinstalltheKT‐0000168(4”)orKT‐0000195(10”)Bracke
MCED-100 MetaCarrier Embedding Device Revision 1 Installation MN-MCED100 2–6 Notes:
3–1 Chapter 3. REAR PANEL CONNECTORS AND PINOUTS 3.1 Cabling Connection Types The MCED‐100 MetaCarrier® Embedding Device uses a number of di
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–2 • Threaded Coupling Style: The jack features
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–3 3.1.2 D-Subminiature Cable Connections Type‘D’C
Thispageisintentionallyblank.
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–4 3.2 MCED-100 Connector Overview The rear panel
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–5 3.3 IF Connections THERE MAY BE DC VOLTAGES
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–6 3.4.1 GPS INPUT | EXTERNAL ANTENNA Connector, Typ
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–7 3.5 Utility Connections 3.5.1 ETHERNET MANAGEMEN
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–8 3.6 MCED-100 Ground and Power Connections 3.6.1
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–9 3.6.2 Alternating Current (AC) Power Interface (S
MCED-100 MetaCarrier Embedding Device Revision 1 Rear Panel Connectors and Pinouts MN-MCED100 3–10 3.6.2.2 AC Operation (Standard) – Replacing Fuse
4–1 Chapter 4. UPDATING FIRMWARE 4.1 Updating Firmware via the Internet TOENSUREOPTIMALPERFORMANCE,ITISIMPORTANTTOOPERATETHEMCED‐100WITH
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–2 4.2 Getting Started: Preparing for the Firmware Download 1. Firs
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–3 D. OnthePC:Reviewandrecordtheinformationdispl ayedonthe
iii TABLE OF CONTENTS TABLE OF CONTENTS ...
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–4 2. Next,createatemporaryfolder(subdirectory)ontheuserPC
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–5 • Click[Browse]inthe“Run”window.The“Browse”windowwillo
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–6 4.3 Downloading and Extracting the Firmware Update 1. First,dow
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–7 o Click[Open]toturnoverfileextractiontotheuser‐supplied
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–8 • Type “dir” to list the files extracted to the temporar
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–9 • OncetheManagementIPaddressisknown–useComma
MCED-100 MetaCarrier Embedding Device Revision 1 Updating Firmware MN-MCED100 4–10 B. ReboottheMCED‐100:• GotoeithertheWebServerInterfac
5–1 Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT 5.1 Introduction 1. To proceed with the MCED‐100 MetaCarrier® Embedding Device’s Seria
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–2 2. USEOFTHESERIAL‐BASEDREMOTEPRODUCTMA
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–3 Whentheuser‐suppliedterminal emulatorpro
MCED-100 MetaCarrier Embedding Device Revision 1 Table of Contents MN-MCED100 iv 1.2.2 Compatibility...
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–4 5.2.2 Packet Structure The exchange of in
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–5 5.2.2.1 Start of Packet Controller‐to‐Target
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–6 5.2.2.5 Instruction Code Qualifier Thisisa
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–7 Character Definition ! (ASCII code 33) If th
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–8 5.3 Remote Commands and Queries TheSerialI
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–9 Parameter Type Command (Instruction & Qua
MCED-100 MetaCarrier Embedding Device Revision 1 Serial-based Remote Product Management MN-MCED100 5–10 Notes:
6–1 Chapter 6. ETHERNET-BASED REMOTE PRODUCT MANAGEMENT 6.1 Introduction Ethernet‐basedRemoteProductManagementisavailablethroughtheMCED‐100
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–2 THEMCED‐100WEBSERVERINTERFACEFORMONI
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–3 6.3 SNMP Interface The Simple Network
MCED-100 MetaCarrier Embedding Device Revision 1 Table of Contents MN-MCED100 v 3.6 MCED‐100GroundandPowerConnections...
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–4 TheuserdefinestwoCommunityStringsfor
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–5 6.4.2 Web Server Interface – Operational
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–6 explanatory,e.g.,[Submit],[Clear],[Ref
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–7 6.4.4 Web Server Interface Page Descripti
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–8 6.4.4.1.2 Home | Contact Use this page
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–9 6.4.4.2 Admin (Administration) Pages Use
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–10 6.4.4.2.2 Admin | SNMP Sect.6.3SNMPI
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–11 6.4.4.2.3 Admin | Firmware Chapter4.U
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–12 Once the unit reboots, the user mu
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–13 • CarrierOperator–Usethisboxtoent
MCED-100 MetaCarrier Embedding Device Revision 1 Table of Contents MN-MCED100 vi 6.4.2.1 VirtualFrontPanel...
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–14 6.4.4.3.2 Configuration | Interface Use
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–15 6.4.4.4 Status Pages TheStatuspagespr
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–16 • GPSLatitude–Thisis thelatitudet
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–17 Click[Refresh]tosaveanychangesand
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–18 6.4.4.5 Utility Pages ClicktheMiscella
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–19 • SetTime(hh:mm:ss)–UseHH:MM:SSfor
MCED-100 MetaCarrier Embedding Device Revision 1 Ethernet-based Remote Product Management MN-MCED100 6–20 • DataBits–Usethedrop‐downmenut
A–1 Appendix A. INTERFERENCE IDENTIFICATION A.1 Introduction WithoutCarrierIDtechnology,theabilitytoidentifycarriersisacomplextaskeven
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–2 A.2 Scenario 1: Marginal Interference Item Descriptio
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–3 A.3 Scenario 2: Marginal Interference Item Descriptio
MCED-100 MetaCarrier Embedding Device Revision 1 Table of Contents MN-MCED100 vii FIGURES Figure1‐1.MCED‐100MetaCarrierEmbeddingDevice...
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–4 Onceaninterferingcarrierisfound,theuplinkingstationcanbecontac
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–5 A.5 Scenario 4: Complete Interference Item Descripti
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–6 A.6 Scenario 5: Complete Interference Item Descr
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–7 As before, 50% probability is assumed, since the MCxD‐100 must
MCED-100 MetaCarrier Embedding Device Revision 1 Appendix A MN-MCED100 A–8 Notes:
METRIC CONVERSIONS Units of Length Unit Millimeter Centimeter Inch Foot Yard Meter Kilometer Mile 1 millimeter 1 0.1 0.0394 0.0033 0.0
2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX